High-oxygen-transmissibility soft contact lenses do not induce limbal hyperaemia.

E B Papas1, C M Vajdic, R Austen, B A Holden.   

Abstract

PURPOSE: To establish the temporal sequence of limbal hyperaemia in humans without contact-lens wear and during conventional and highly oxygen-permeable soft-contact-lens wear.
METHODS: Two, 16-h, non-dispensing clinical studies were conducted, each incorporating 8 h of open eye with normal blinking, followed by 8 h of eye closure during sleep. In the first study, six non-habitual contact-lens wearers did not wear contact lenses. In the second study, the same subjects were each randomly assigned, in a double-masked fashion, to wear a conventional, thin, 38% water, pHEMA soft contact lens (SCL) in one eye and an experimental high Dk (EHD), 20%-water soft contact lens in the other. Limbal redness (LR) was graded, using a 0-4 scale with decimalised subdivisions, at baseline and after 4, 8 and 16 h. ANOVA was applied to the data, and the level for statistical significance was set at p < or = 0.005.
RESULTS: In the non-wearing eye, LR changes averaged 0.2 +/- 0.2 and 0.4 +/- 0.2 grades at 4 and 16 h, respectively (inferior quadrant). The corresponding values for SCL wear were 1.0 +/- 0.6 and 1.1 +/- 0.6, while for EHD wear they were 0.2 +/- 0.4 and 0.5 +/- 0.5. Both for the normal eye and those wearing EHD lenses, increases in LR were significant only during eye closure (p < 0.005). During SCL wear, significant and larger LR increases were seen after 4 h open eye wear (p < 0.005), with only relatively small further changes being observed over the next 12 h.
CONCLUSIONS: SCL wear induces a marked increase in limbal hyperaemia during open-eye wear, which is not seen either in the no lens situation or when EHD lenses are worn. The pattern of limbal hyperaemia for both the open and closed eyes during EHD lens wear is very similar to that for the no-lens situation. The mechanism whereby SCL induces excess limbal hyperaemia has not been absolutely established, but it may involve local hypoxia.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9288457     DOI: 10.1076/ceyr.16.9.942.5049

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  5 in total

1.  Short term wear of high Dk soft contact lenses does not alter corneal epithelial cell size or viability.

Authors:  F Stapleton; S Kasses; S Bolis; L Keay
Journal:  Br J Ophthalmol       Date:  2001-02       Impact factor: 4.638

2.  Risk factors for corneal infiltrative events during continuous wear of silicone hydrogel contact lenses.

Authors:  Loretta Szczotka-Flynn; Jonathan H Lass; Ajay Sethi; Sara Debanne; Beth Ann Benetz; Matthew Albright; Beth Gillespie; Jana Kuo; Michael R Jacobs; Alfred Rimm
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-06-10       Impact factor: 4.799

3.  Cytokine changes in tears and relationship to contact lens discomfort.

Authors:  Mark D P Willcox; Zhenjun Zhao; Thomas Naduvilath; Percy Lazon de la Jara
Journal:  Mol Vis       Date:  2015-03-15       Impact factor: 2.367

4.  A Survey of Contact Lens Wearers and Eye Care Professionals on Satisfaction with a New Smart-Surface Silicone Hydrogel Daily Disposable Contact Lens.

Authors:  Timothy Grant; Anson Tang
Journal:  Clin Optom (Auckl)       Date:  2020-01-14

5.  Corneal Swelling with Cosmetic etafilcon A Lenses versus No Lens Wear.

Authors:  Amir M Moezzi; Jalaiah Varikooty; Marc Schulze; William Ngo; Kathrine Osborn Lorenz; Danielle Boree; Lyndon W Jones
Journal:  Optom Vis Sci       Date:  2016-06       Impact factor: 1.973

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.