Literature DB >> 9286606

Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions.

H Benoit1, F Costes, L Feasson, J R Lacour, F Roche, C Denis, A Geyssant, J C Barthélémy.   

Abstract

There is a growing need to measure arterial oxygen saturation with a non-invasive method during heavy exercise under severe hypoxic conditions. Although the accuracy of pulse oximetry has been challenged by several authors, it has not been done under extreme conditions. The purpose of this study was to evaluate the accuracy of a pulse oximeter (Satllite. Datex, Finland) during exercise under hypoxic conditions where arterial oxygen saturation was below 75%, simulating exercise at extreme altitude. Ten healthy non-smoking men performed two exercise studies of 30 min under normoxia and under hypoxia on two consecutive days. The exercise intensity was 80% of maximal O2 consumption of VO2max. Arterial oxygen saturation measured by pulse oximetry was corrected (SpO2[corr]) according to previously published equations and was compared to arterial oxygen saturation (SaO2) in blood samples taken simultaneously from the radial artery. Reference arterial saturation values ranged from 57.2 to 97.6% for the whole data set. This data set was split according to low (SaO2 < or = 75%) and high (SaO2 > 75%) SaO2 values. The error of pulse oximetry (SpO2[corr]-SaO2) was 2.05 (0.87)% [mean (SD)] and 1.80 (1.81)% for high and low SaO2 values, respectively. SpO2[corr] and SaO2 were highly correlated (r = 0.93, SEE = 1.81) for low values. During high-intensity constant workload under severe hypoxic conditions, once corrected, pulse oximetry provides an estimate of SaO2 with a mean error of 2%. Thus, the correction previously described for SpO2 values above 75% saturation applies also to SpO2 values in the range of 57-75% during exercise under hypoxic conditions.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9286606     DOI: 10.1007/s004210050245

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  7 in total

1.  Effect of moderate altitude on peripheral muscle oxygenation during leg resistance exercise in young males.

Authors:  Kazuo Oguri; Na Du; Yoshihiro Kato; Kei Miyamoto; Takahiro Masuda; Katsuji Shimizu; Toshio Matsuoka
Journal:  J Sports Sci Med       Date:  2004-09-01       Impact factor: 2.988

2.  Aggravated hypoxia during breath-holds after prolonged exercise.

Authors:  Peter Lindholm; Mikael Gennser
Journal:  Eur J Appl Physiol       Date:  2004-11-25       Impact factor: 3.078

3.  Effect of hyperoxia on maximal O2 uptake in exercise-induced arterial hypoxaemic subjects.

Authors:  Olivier Grataloup; Fabrice Prieur; Thierry Busso; Josiane Castells; François B Favier; Christian Denis; Henri Benoit
Journal:  Eur J Appl Physiol       Date:  2005-06-08       Impact factor: 3.078

4.  Decrease in peak heart rate with acute hypoxia in relation to sea level VO(2max).

Authors:  Henri Benoit; Thierry Busso; Josiane Castells; Andre Geyssant; Christian Denis
Journal:  Eur J Appl Physiol       Date:  2003-07-26       Impact factor: 3.078

5.  Effects of fasting and carbohydrate consumption on voluntary resting apnea duration.

Authors:  Peter Lindholm; Mary Conniff; Mikael Gennser; David Pendergast; Claes Lundgren
Journal:  Eur J Appl Physiol       Date:  2007-04-04       Impact factor: 3.346

6.  Oxygen Saturation Behavior by Pulse Oximetry in Female Athletes: Breaking Myths.

Authors:  Pilar Martín-Escudero; Ana María Cabanas; Manuel Fuentes-Ferrer; Mercedes Galindo-Canales
Journal:  Biosensors (Basel)       Date:  2021-10-14

7.  Wearable Sensor System to Monitor Physical Activity and the Physiological Effects of Heat Exposure.

Authors:  Sean Pham; Danny Yeap; Gisela Escalera; Rupa Basu; Xiangmei Wu; Nicholas J Kenyon; Irva Hertz-Picciotto; Michelle J Ko; Cristina E Davis
Journal:  Sensors (Basel)       Date:  2020-02-06       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.