Literature DB >> 9282868

Extraneous lipid contamination in single-volume proton MR spectroscopy: phantom and human studies.

L Kwock1, M A Brown, M Castillo.   

Abstract

PURPOSE: To determine the degree of extraneous lipid contamination in defined volumes of interest studied with single-volume proton MR spectroscopy.
METHODS: Single-volume proton MR spectroscopy was performed on a fat/water phantom and in three volunteers using the stimulated-echo acquisition mode (STEAM) and point-resolved spectroscopy (PRESS) localization methods. Three different volumes of interest (8, 27, and 64 cm3) were examined at echo times of 20, 135, and 270 for the STEAM sequences and 135 and 270 for the PRESS acquisitions in both the phantom and the volunteers (volumes of interest were placed adjacent to but not encompassing fat-containing structures, such as the scalp and retroorbital fat). The degree of lipid contamination was then correlated with measurements of the section profiles.
RESULTS: The PRESS method resulted in less extraneous lipid contamination in both phantom and volunteer studies. The STEAM method had the highest level of lipid contamination signal in phantom and human studies. In the volunteers, volumes of interest abutting fat-containing structures obtained with PRESS or STEAM sequences showed no lipid contamination. However, the STEAM sequences showed lipid signal in the volume of interest adjacent to orbital fat whereas the PRESS sequences did not. These observations are supported by the section profile studies, which showed that the actual volume excited by the STEAM sequence was 7% to 32% larger than that originally selected, while with PRESS the actual excited volume was 12% to 16% smaller than that originally selected.
CONCLUSION: In our MR unit, short-echo-time STEAM sequences (< or = 135 milliseconds) resulted in extraneous lipid contamination in phantom and human studies adjacent to the orbits. PRESS sequences showed no lipid contamination in volumes abutting fat structures in phantoms or humans. These results correlated closely with the configuration of the section profiles. Although these findings might be dependent on the MR unit used, our study could help determine extraneous lipid contamination for other MR units.

Entities:  

Mesh:

Year:  1997        PMID: 9282868      PMCID: PMC8338041     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  5 in total

1.  Proton MR spectroscopy in patients with acute temporal lobe seizures.

Authors:  M Castillo; J K Smith; L Kwock
Journal:  AJNR Am J Neuroradiol       Date:  2001-01       Impact factor: 3.825

2.  Serial proton MR spectroscopy of contrast-enhancing multiple sclerosis plaques: absolute metabolic values over 2 years during a clinical pharmacological study.

Authors:  I Mader; W Roser; L Kappos; G Hagberg; J Seelig; E W Radue; W Steinbrich
Journal:  AJNR Am J Neuroradiol       Date:  2000-08       Impact factor: 3.825

3.  3T 1H-MR spectroscopy in grading of cerebral gliomas: comparison of short and intermediate echo time sequences.

Authors:  J-h Kim; K-H Chang; D G Na; I C Song; B J Kwon; M H Han; K Kim
Journal:  AJNR Am J Neuroradiol       Date:  2006-08       Impact factor: 3.825

4.  Slice with angulated non-parallel boundaries.

Authors:  Busik Park; Martin J Lizak; Yun Xiang; Jun Shen
Journal:  J Magn Reson       Date:  2011-02-18       Impact factor: 2.229

5.  Proton MR spectroscopy in children with bipolar affective disorder: preliminary observations.

Authors:  M Castillo; L Kwock; H Courvoisie; S R Hooper
Journal:  AJNR Am J Neuroradiol       Date:  2000-05       Impact factor: 4.966

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.