Literature DB >> 9275700

The value of perioperative echocardiography in percutaneous balloon mitral valvuloplasty.

Q Lu1, X Wang, L Cao, Z Li, Y Yang, L Liu.   

Abstract

In order to investigate the value of perioperative echocardiography in percutaneous balloon mitral valvuloplasty (PBMV), two-dimensional echocardiography (2-DE), Doppler echocardiography and color Doppler flow imaging (CDFI) were employed prior to PBMV in 52 patients and during or after PBMV in 15 patients. The results showed that TTE and TEE were helpful in the selection of candidates for 2-DE transseptal and balloon dilation procedures. Continuous monitoring of 2-DE, Doppler echocardiography and CDFI during PBMV could make this procedure safer and more effective, reduce X-ray exposure and avoid complications. Echocardiography was useful in fluoroscopy and could be used for evaluation of the effects of operation.

Entities:  

Mesh:

Year:  1996        PMID: 9275700     DOI: 10.1007/bf02887965

Source DB:  PubMed          Journal:  J Tongji Med Univ        ISSN: 0257-716X


  6 in total

1.  Role of transesophageal echocardiography in percutaneous balloon mitral valvuloplasty.

Authors:  K Chan; J Marquis; C Ascah; B Morton; M Baird
Journal:  Echocardiography       Date:  1990-03       Impact factor: 1.724

2.  Value and limitations of transesophageal echocardiographic monitoring during percutaneous balloon mitral valvotomy.

Authors:  A Ramondo; F Chirillo; M Dan; G Isabella; R Bonato; C Rampazzo; R Razzolini; L Andriolo; A Mazzucco; R Chioin
Journal:  Int J Cardiol       Date:  1991-05       Impact factor: 4.164

3.  The role of echocardiography/Doppler in catheter balloon treatment of adults with aortic and mitral stenosis.

Authors:  C L Reid; S H Rahimtoola
Journal:  Circulation       Date:  1991-09       Impact factor: 29.690

4.  The transponder system: a new method of precise catheter placement in the right atrium under echocardiographic guidance.

Authors:  J S Landzberg; J O Franklin; J J Langberg; J M Herre; M M Scheinman; N B Schiller
Journal:  J Am Coll Cardiol       Date:  1988-09       Impact factor: 24.094

5.  Transesophageal echocardiography to detect atrial clots in candidates for percutaneous transseptal mitral balloon valvuloplasty.

Authors:  I Kronzon; P A Tunick; E Glassman; J Slater; M Schwinger; R S Freedberg
Journal:  J Am Coll Cardiol       Date:  1990-11       Impact factor: 24.094

6.  Clinical application of transvenous mitral commissurotomy by a new balloon catheter.

Authors:  K Inoue; T Owaki; T Nakamura; F Kitamura; N Miyamoto
Journal:  J Thorac Cardiovasc Surg       Date:  1984-03       Impact factor: 5.209

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.