Immediate, quantitative estimation of blood alcohol concentration from saliva.

M E Bates1, C S Martin.   

Abstract

OBJECTIVE: Reliable, valid, and noninvasive methods to quantitatively estimate blood alcohol concentration (BAC) are important in forensic, work place, medical and research settings. To date, noninvasive methods for quantitatively estimating BAC have primarily used breath testing. This study evaluated a new device for estimating BAC via saliva that is unique in providing on-the-spot, quantitative results in 2 minutes. The Q.E.D-A150 test (STC Technologies, Inc., Bethlehem, Pa.) is based on the enzymatic oxidation of alcohol by alcohol dehydrogenase. Saliva alcohol concentration (SAC) is read directly from the test device.
METHOD: In each of three sessions, 24 male and 15 female social drinkers, aged 21-28 years, provided yoked breath and saliva samples prior to, and at five times following, a dose of 1.0 g (men) or 0.9 g (women) alcohol per kg lean body mass.
RESULTS: Intertest reliability, determined by two simultaneous saliva samples, was very high for each measurement time (r's = .97 to .99), for each subject (4's = .95 to .99) and across all observations (r = .98). The coefficient of variation was below 5% in 97% of paired observations. The correlation between breath and saliva estimates was .94 across all observations and ranged from .92 to .98 across measurement times. The difference between breath and saliva estimates was significantly larger on the ascending limb than on the descending limb of the blood alcohol curve at comparable BACs. On the average, SAC estimates were 6 mg/dl higher than breath during ascending BACs and 3 mg/dl higher than breath during descending BACs. Individual differences in the ratio of SAC to breath measures of BAC ranged from 0.99 to 1.15 (average = 1.06). Test performance was not affected by gender, drinking pattern or cigarette smoker status.
CONCLUSIONS: The Q.E.D.-A150 device had good reliability and validity for the noninvasive, quantitative estimation of BACs.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9273920     DOI: 10.15288/jsa.1997.58.531

Source DB:  PubMed          Journal:  J Stud Alcohol        ISSN: 0096-882X


  4 in total

1.  Wearable Electrochemical Alcohol Biosensors.

Authors:  Alan S Campbell; Jayoung Kim; Joseph Wang
Journal:  Curr Opin Electrochem       Date:  2018-05-23

2.  Acute alcohol intake alters resting state functional connectivity of nucleus accumbens with pain-related corticolimbic structures.

Authors:  Jeff Boissoneault; Bethany Stennett; Michael E Robinson
Journal:  Drug Alcohol Depend       Date:  2019-12-24       Impact factor: 4.492

3.  Acute Tolerance to the Analgesic Effects of Alcohol.

Authors:  Michelle K Williams; Darya Vitus; Erin Ferguson; Bethany Stennett; Michael Robinson; Jeff Boissoneault
Journal:  J Stud Alcohol Drugs       Date:  2021-05       Impact factor: 2.582

4.  Immediate and Complex Cardiovascular Adaptation to an Acute Alcohol Dose.

Authors:  Jennifer F Buckman; David Eddie; Evgeny G Vaschillo; Bronya Vaschillo; Aaron Garcia; Marsha E Bates
Journal:  Alcohol Clin Exp Res       Date:  2015-11-28       Impact factor: 3.928

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.