| Literature DB >> 9273379 |
J F John1, R E Talbert, J K Taylor, W L Bargar.
Abstract
The number of patients requiring revision total hip arthroplasty continues to increase each year. Accurate preoperative planning is a key factor in obtaining a good result. Radiographs provide little information concerning the actual extent of the acetabular defects. Computed tomography-generated models of the acetabulum can provide the surgeon with accurate information concerning the size and location of the defects. Evaluation of radiographs and models in 24 cases showed that radiographs alone failed to detect all 13 anterior wall defects (P < .001), 8 of 18 posterior wall defects (44.4%, P < .001), and 8 of 19 segmental central defects (42%, P < .001), all of which were easily identified with the models. This study showed that preoperative planning based on the foam models accurately predicted the actual implant used in 22 of 24 cases (92%).Entities:
Mesh:
Year: 1995 PMID: 9273379 DOI: 10.1016/s0883-5403(05)80212-8
Source DB: PubMed Journal: J Arthroplasty ISSN: 0883-5403 Impact factor: 4.757