Literature DB >> 9267942

Practice guideline for arterial blood gas measurement in the intensive care unit decreases numbers and increases appropriateness of tests.

C S Pilon1, M Leathley, R London, S McLean, P T Phang, R Priestley, F M Rosenberg, J Singer, A H Anis, P M Dodek.   

Abstract

OBJECTIVE: To test the hypothesis that implementation of a practice guideline for blood gas measurement would decrease numbers and increase appropriateness of tests (according to criteria in the guideline) for up to 1 yr after introduction of the guideline.
DESIGN: Numbers of tests and appropriateness of each test were measured retrospectively during each of five periods: two baseline periods 2 yrs and 1 yr before introduction of the guideline and three follow-up periods 2 to 3 months, 6 to 7 months, and 12 to 13 months after introduction of the guideline.
SETTING: A ten-bed multidisciplinary intensive care unit (ICU) within a 500-bed tertiary teaching hospital. PATIENTS: A random sample of 30 patients admitted to the ICU during each of the periods specified above.
INTERVENTIONS: The nominal group process was used to develop a new guideline and a multipronged educational approach was used to facilitate implementation of the guideline.
MEASUREMENTS AND MAIN RESULTS: At 2 to 3 months, test numbers decreased from 4.9 +/- 1.6 to 3.1 +/- 1.8 (SD) tests/patient/day and to 2.4 +/- 1.2 tests/patient/day at 12 to 13 months. Appropriateness increased from a mean of 44% at baseline to 78% at 2 to 3 months and 79% at 12 to 13 months. There were no differences in Acute Physiology and Chronic Health Evaluation scores or ICU mortality among the patient groups and no differences in number of ventilator days or time to wean from ventilation. Cost-minimization analysis showed that the incremental cost-saving 1 yr after introduction of the guideline was $19.18 per patient per day.
CONCLUSIONS: Implementation of this guideline for arterial blood gas measurement increases efficiency of test utilization without prolonging mechanical ventilation or affecting outcome.

Entities:  

Mesh:

Year:  1997        PMID: 9267942     DOI: 10.1097/00003246-199708000-00016

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  13 in total

Review 1.  Practice guidelines and measurement: state-of-the-science.

Authors:  Patricia C Dykes
Journal:  Nurs Outlook       Date:  2003 Mar-Apr       Impact factor: 3.250

2.  Clinical Characteristics and Outcomes Are Similar in ARDS Diagnosed by Oxygen Saturation/Fio2 Ratio Compared With Pao2/Fio2 Ratio.

Authors:  Wei Chen; David R Janz; Ciara M Shaver; Gordon R Bernard; Julie A Bastarache; Lorraine B Ware
Journal:  Chest       Date:  2015-12       Impact factor: 9.410

3.  Recommendations for the transfusion management of patients in the peri-operative period. III. The post-operative period.

Authors:  Giancarlo Maria Liumbruno; Francesco Bennardello; Angela Lattanzio; Pierluigi Piccoli; Gina Rossetti
Journal:  Blood Transfus       Date:  2011-04-20       Impact factor: 3.443

4.  Preventing ARDS: progress, promise, and pitfalls.

Authors:  Jeremy R Beitler; David A Schoenfeld; B Taylor Thompson
Journal:  Chest       Date:  2014-10       Impact factor: 9.410

5.  Quality improvement report: Linking guideline to regular feedback to increase appropriate requests for clinical tests: blood gas analysis in intensive care.

Authors:  P Merlani; P Garnerin; M Diby; M Ferring; B Ricou
Journal:  BMJ       Date:  2001-09-15

6.  Design and Rationale of the Reevaluation of Systemic Early Neuromuscular Blockade Trial for Acute Respiratory Distress Syndrome.

Authors:  David T Huang; Derek C Angus; Marc Moss; B Taylor Thompson; Niall D Ferguson; Adit Ginde; Michelle Ng Gong; Stephanie Gundel; Douglas L Hayden; R Duncan Hite; Peter C Hou; Catherine L Hough; Theodore J Iwashyna; Kathleen D Liu; Daniel S Talmor; Donald M Yealy
Journal:  Ann Am Thorac Soc       Date:  2017-01

7.  Characteristics of children intubated and mechanically ventilated in 16 PICUs.

Authors:  Robinder G Khemani; Barry P Markovitz; Martha A Q Curley
Journal:  Chest       Date:  2009-06-19       Impact factor: 9.410

8.  Clinicians' response to hyperoxia in ventilated patients in a Dutch ICU depends on the level of FiO2.

Authors:  Aafke Elizabeth de Graaff; Dave Anton Dongelmans; Jan Maria Binnekade; Evert de Jonge
Journal:  Intensive Care Med       Date:  2010-09-28       Impact factor: 17.440

9.  Comparison of the spo2/fio2 ratio and the pao2/fio2 ratio in patients with acute lung injury or acute respiratory distress syndrome.

Authors:  Nemat Bilan; Azar Dastranji; Afshin Ghalehgolab Behbahani
Journal:  J Cardiovasc Thorac Res       Date:  2015-03-29

10.  A review on laboratory tests' utilization: A trigger for cutting costs and quality improvement in health care settings.

Authors:  Zahra Meidani; Mehrdad Farzandipour; Alireza Farrokhian; Masomeh Haghighat
Journal:  Med J Islam Repub Iran       Date:  2016-05-08
View more