Literature DB >> 9265424

Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter. A randomized, controlled trial.

D G Maki1, S M Stolz, S Wheeler, L A Mermel.   

Abstract

BACKGROUND: Bloodstream infection related to short-term use of noncuffed central venous catheters is a common and serious problem. Technologic innovations to reduce the risk for these infections are needed.
OBJECTIVE: To determine 1) the efficacy of a novel antiseptic catheter in preventing central venous catheter-related infection, 2) patient tolerance of this catheter, and 3) the sources of bloodstream infection originating from noncuffed, multilumen central venous catheters.
DESIGN: Randomized, controlled clinical trial.
SETTING: Medical-surgical intensive care unit of a 450-bed university hospital. PARTICIPANTS: 158 adults scheduled to receive a central venous catheter; 403 catheters were studied. INTERVENTION: Participants received either a standard triple-lumen polyurethane catheter or a catheter that was indistinguishable from the standard catheter and was impregnated with chlorhexidine and silver sulfadiazine. MEASUREMENTS: Catheters were studied for colonization and catheter-related bloodstream infection at removal; local and systemic effects of catheters were assessed. The origin of each catheter-associated bloodstream infection was sought by culturing all potential sources (skin, catheter segments, hubs, and infusate) and confirmed by restriction-fragment DNA subtyping.
RESULTS: Antiseptic catheters were less likely to be colonized at removal than control catheters (13.5 compared with 24.1 colonized catheters per 100 catheters; relative risk, 0.56 [95% CI, 0.36 to 0.89]; P = 0.005) and were nearly fivefold less likely to produce bloodstream infection (1.0 compared with 4.7 infections per 100 catheters; 1.6 compared with 7.6 infections per 1000 catheter-days; relative risk, 0.21 [CI, 0.03 to 0.95]; P = 0.03). In the control group, 8 catheter-related bloodstream infections were caused by Staphylococcus aureus, gram-negative bacilli, enterococci, or Candida species; no infections with these organisms occurred in the antiseptic catheter group (P = 0.003). No adverse effects from the antiseptic catheter were seen, and none of the 122 isolates obtained from infected catheters in either group showed in vitro resistance to chlorhexidine-silver sulfadiazine. Cost-benefit analysis indicated that the antiseptic catheter should prove cost-beneficial if an institution's rate of catheter-related bacteremia with noncuffed central venous catheters is at least 3 infections per 1000 catheter-days).
CONCLUSIONS: The chlorhexidine-silver sulfadiazine catheter is well tolerated, reduces the incidence of catheter-related infection, extends the time that noncuffed central venous catheters can be safely left in place for the short term, and should allow cost savings.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9265424     DOI: 10.7326/0003-4819-127-4-199708150-00001

Source DB:  PubMed          Journal:  Ann Intern Med        ISSN: 0003-4819            Impact factor:   25.391


  100 in total

Review 1.  Diagnosis of central venous catheter related sepsis--a critical look inside.

Authors:  B M Dobbins; P Kite; M H Wilcox
Journal:  J Clin Pathol       Date:  1999-03       Impact factor: 3.411

2.  Economic aspects of innovations in medical technology.

Authors:  P Oberender; S Ruckdäschel; S Lugauer; J P Guggenbichler
Journal:  Infection       Date:  1999       Impact factor: 3.553

3.  Catheter-Related Bloodstream Infection.

Authors: 
Journal:  Curr Infect Dis Rep       Date:  1999-08       Impact factor: 3.725

4.  Nosocomial Infections in the Intensive Care Unit Associated with Invasive Medical Devices.

Authors:  Nasia Safdar; Christopher J. Crnich; Dennis G. Maki
Journal:  Curr Infect Dis Rep       Date:  2001-12       Impact factor: 3.725

5.  Durability of anti-infective effect of long-term silicone sheath catheters impregnated with antimicrobial agents.

Authors:  R K Tcholakian; I I Raad
Journal:  Antimicrob Agents Chemother       Date:  2001-07       Impact factor: 5.191

Review 6.  Catheter-related infections in pediatric patients with cancer.

Authors:  V Cecinati; L Brescia; L Tagliaferri; P Giordano; S Esposito
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2012-06-03       Impact factor: 3.267

7.  Bacteriocins Pep5 and epidermin inhibit Staphylococcus epidermidis adhesion to catheters.

Authors:  Mariana Buss Cezar Fontana; Maria do Carmo Freire de Bastos; Adriano Brandelli
Journal:  Curr Microbiol       Date:  2006-04-01       Impact factor: 2.188

8.  Prevention of catheter related bloodstream infection by silver iontophoretic central venous catheters: a randomised controlled trial.

Authors:  J J Bong; P Kite; M H Wilco; M J McMahon
Journal:  J Clin Pathol       Date:  2003-10       Impact factor: 3.411

9.  Persistent bacteremia in the absence of defined intravascular foci: clinical significance and risk factors.

Authors:  M Y Chowers; B Gottesman; M Paul; M Weinberger; S Pitlik; L Leibovici
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2003-09-25       Impact factor: 3.267

10.  Silver toxicity with the use of silver-impregnated dressing and wound vacuum-assisted closure in an immunocompromised patient.

Authors:  Cabrini A Lariviere; Adam B Goldin; Jeffrey Avansino
Journal:  J Am Col Certif Wound Spec       Date:  2011-05-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.