Literature DB >> 9261733

Effect of electrode positioning on ECG interpretation by computer.

B J Schijvenaars1, J A Kors, G van Herpen, F Kornreich, J H van Bemmel.   

Abstract

The aim of this study was to assess the variability in automated electrocardiogram (ECG) interpretation due to electrode positioning variations. Such variations were simulated by using a set of 746 body surface potential mappings from apparently healthy individuals and patients with myocardial infarction or left ventricular hypertrophy. Four types of electrode position changes were simulated, and the effect on ECG measurements and diagnostic classifications was determined by a computer program. At most 6% of the cases showed important changes in classification for longitudinal shifts. Transversal shifts causes less than 1.5% of important changes. An expert cardiologist, who analyzed a subset of 80 cases, agreed with the computer in 38 of 40 cases in which it made no change. In the 40 cases with large diagnostic changes, the cardiologist made no change in 18 cases. The effect of electrode position changes on ECG classification by an expert cardiologist was about half of the effect determined by computerized ECG classification. The effects on classification are significant; therefore, correct placement of chest electrodes remains mandatory.

Entities:  

Mesh:

Year:  1997        PMID: 9261733     DOI: 10.1016/s0022-0736(97)80010-6

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  7 in total

1.  Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living.

Authors:  Søren Brage; Niels Brage; Ulf Ekelund; Jian'an Luan; Paul W Franks; Karsten Froberg; Nicholas J Wareham
Journal:  Eur J Appl Physiol       Date:  2005-12-13       Impact factor: 3.078

2.  The Reconstruction of a 12-Lead Electrocardiogram from a Reduced Lead Set Using a Focus Time-Delay Neural Network.

Authors:  Gerard H Smith; Dawie J Van den Heever; Wayne Swart
Journal:  Acta Cardiol Sin       Date:  2021-01       Impact factor: 2.672

3.  Effect of increased left ventricle mass on ischemia assessment in electrocardiographic signals: rabbit isolated heart study.

Authors:  Marina Ronzhina; Veronika Olejnickova; Tibor Stracina; Marie Novakova; Oto Janousek; Jakub Hejc; Jana Kolarova; Miroslava Hlavacova; Hana Paulova
Journal:  BMC Cardiovasc Disord       Date:  2017-08-04       Impact factor: 2.298

4.  Chest-lead ST-J amplitudes using arm electrodes as reference instead of the Wilson central terminal in smartphone ECG applications: Influence on ST-elevation myocardial infarction criteria fulfillment.

Authors:  Thomas Lindow; Henrik Engblom; Ardavan Khoshnood; Ulf Ekelund; Marcus Carlsson; Olle Pahlm
Journal:  Ann Noninvasive Electrocardiol       Date:  2018-05-07       Impact factor: 1.468

Review 5.  Computational Diagnostic Techniques for Electrocardiogram Signal Analysis.

Authors:  Liping Xie; Zilong Li; Yihan Zhou; Yiliu He; Jiaxin Zhu
Journal:  Sensors (Basel)       Date:  2020-11-05       Impact factor: 3.576

6.  The effect of precordial lead displacement on ECG morphology.

Authors:  Michał Kania; Hervé Rix; Małgorzata Fereniec; Heriberto Zavala-Fernandez; Dariusz Janusek; Tomasz Mroczka; Günter Stix; Roman Maniewski
Journal:  Med Biol Eng Comput       Date:  2013-10-19       Impact factor: 2.602

7.  Perspectives of human verification via binary QRS template matching of single-lead and 12-lead electrocardiogram.

Authors:  Vessela Krasteva; Irena Jekova; Ramun Schmid
Journal:  PLoS One       Date:  2018-05-17       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.