Literature DB >> 9260630

Closed rupture of a finger extensor following the Sauvé-Kapandji procedure: a case report.

T Wada1, T Ogino, S Ishii.   

Abstract

A case of closed rupture of the ring extensor digitorum tendon following performance of the Sauvé-Kapandji procedure is presented. This complication is not rare following performance of the Darrach procedure. The operative findings indicated that the rupture was caused by an impingement of the tendon between the proximal stump of the ulna and the extensor retinaculum. The patient was successfully treated with shortening of the proximal ulnar stump and tendon transfer.

Entities:  

Mesh:

Year:  1997        PMID: 9260630     DOI: 10.1016/S0363-5023(97)80132-3

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  1 in total

1.  Extensor tendon rupture of finger while playing Uileann pipe.

Authors:  S M Ali; D O'Farrel
Journal:  Ir J Med Sci       Date:  2006 Oct-Dec       Impact factor: 1.568