Literature DB >> 9260267

High performance liquid chromatographic analysis of selected sulfonamides in plasma.

J Klimes1, M Mokrý.   

Abstract

Chromatographic conditions were elaborated to evaluate a model mixture of four sulfonamides (sulfamethoxazole, sulfamoxole, sulfisoxazole and sulfamethoxydiazine) in plasma using a reversed phase HPLC C18 column and a mobile phase composed of methanol and phosphate buffer (60:40; v/v) at pH 5.0. The detection was made using an electrochemical detection with the potential set at 1.1 V. In the case of sulfonamides deproteination of plasma with methanol was more advantageous than extraction with organic solvents. The recovery of analysed sulfonamides was in the range of 95-97%, the detection limits were 10 ng/ml of plasma.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9260267

Source DB:  PubMed          Journal:  Pharmazie        ISSN: 0031-7144            Impact factor:   1.267


  1 in total

1.  Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole.

Authors:  Sabriye Perçin Ozkorucuklu; Yücel Sahin; Güleren Alsancak
Journal:  Sensors (Basel)       Date:  2008-12-18       Impact factor: 3.576