Literature DB >> 9259842

Evaluation of the ID-gel test for antibody screening and identification.

I M Bromilow1, K E Adams, J Hope, J A Eggington, J K Duguid.   

Abstract

A gel technique for the detection of red blood cell (rbc) antigen-antibody reactions was evaluated for use in antenatal antibody screening and identification procedures. The evaluation was undertaken on 3,900 random antenatal samples. Results obtained in the gel test system were compared with those obtained from parallel testing using conventional serological methods. The ID gel system detected 148 (3.7%) red cell antibodies, compared with 95 (2.4%) using traditional techniques. The number of non-specific antibodies and false-positive screens were reduced using the gel test system. Antibody titres performed using the gel system were more sensitive than with our tube IAT method. The gel system was easy to use and gave reliable, reproducible results. Antibody detection rates were enhanced compared with our existing routine techniques.

Mesh:

Substances:

Year:  1991        PMID: 9259842     DOI: 10.1111/j.1365-3148.1991.tb00025.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  6 in total

1.  Evaluation of the use of gel card system for assessment of direct coombs test: weighing the pros and cons.

Authors:  Vanamala Alwar; A M Shanthala Devi; S Sitalakshmi; R K Karuna
Journal:  Indian J Hematol Blood Transfus       Date:  2011-07-21       Impact factor: 0.900

2.  Comparative Study of Blood Cross Matching Using Conventional Tube and Gel Method.

Authors:  D Swarup; P S Dhot; J Kotwal; A K Verma
Journal:  Med J Armed Forces India       Date:  2011-07-21

Review 3.  New technology in hospital blood banking.

Authors:  J K Duguid; I M Bromilow
Journal:  J Clin Pathol       Date:  1993-07       Impact factor: 3.411

4.  Detection of alloimmunization to ensure safer transfusion practice.

Authors:  Rashmi Sood; R N Makroo; Vimarsh Riana; N L Rosamma
Journal:  Asian J Transfus Sci       Date:  2013-07

5.  Comparison of micro column technology with conventional tube methods for antibody detection.

Authors:  Sachin Garg; Nishant Saini; Ravneet Kaur Bedi; Sabita Basu
Journal:  J Lab Physicians       Date:  2017 Apr-Jun

6.  Screening and identification of unexpected red cell antibodies by simultaneous LISS/Coombs and NaCl/Enzyme gel methods.

Authors:  Jeong Hwan Shin; Ja Young Lee; Jae Hyen Kim; Hye Ran Kim; Jeong Nyeo Lee
Journal:  J Korean Med Sci       Date:  2009-07-29       Impact factor: 2.153

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.