Literature DB >> 9259339

The new pulmonary artery catheters: continuous venous oximetry, right ventricular ejection fraction, and continuous cardiac output.

L D Nelson1.   

Abstract

OBJECTIVE: To review the literature addressing the new pulmonary artery catheters: continuous venous oximetry, right ventricular ejection fraction, and continuous cardiac output. DATA SOURCE: All pertinent English language literature dealing with new pulmonary artery catheters were retrieved from 1981 through 1996. STUDY SELECTION: Articles were chosen for review if the primary objective of the paper was study or review of technology related to new pulmonary artery catheters. DATA EXTRACTION: From the literature selected, information was obtained about continuous venous oximetry, right ventricular ejection fraction, and continuous cardiac output catheters. DATA SYNTHESIS: When pulmonary artery catheterization is used, continuous venous oximetry catheters may be considered for use when it is anticipated that therapy will be based upon oxygen transport end points. When pulmonary artery catheterization is used, right ventricular ejection fraction catheters may be considered for use when the anticipated therapy will be based upon evaluation of ventricular preload and when central venous pressure and/or pulmonary artery occlusion do not accurately reflect preload. When pulmonary artery catheterization is used, continuous cardiac output catheters may be considered for use in titration of interventions employed to alter stroke volume.
CONCLUSION: Clinician misinterpretation and misapplication of the data appear to be the greatest impediment to using pulmonary artery catheterization to alter pathophysiologic processes and improve outcome in critically ill patients. Future research should first document effectiveness or lack of effectiveness of the "standard" pulmonary artery catheter (PAC). Pending these results, outcome and cost/benefit studies should be performed comparing "standard" with new PACs.

Entities:  

Mesh:

Year:  1997        PMID: 9259339

Source DB:  PubMed          Journal:  New Horiz        ISSN: 1063-7389


  6 in total

1.  Analysis of the ear pulse oximeter waveform.

Authors:  Aymen A Awad; Robert G Stout; M Ashraf M Ghobashy; Hoda A Rezkanna; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2006-04-13       Impact factor: 2.502

Review 2.  [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data].

Authors:  U Wittkowski; C Spies; M Sander; J Erb; A Feldheiser; C von Heymann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

3.  Noninvasive cardiac output monitoring (NICOM): a clinical validation.

Authors:  Pierre Squara; Dominique Denjean; Philippe Estagnasie; Alain Brusset; Jean Claude Dib; Claude Dubois
Journal:  Intensive Care Med       Date:  2007-04-26       Impact factor: 17.440

4.  The relationship between the photoplethysmographic waveform and systemic vascular resistance.

Authors:  Aymen A Awad; Ala S Haddadin; Hossam Tantawy; Tarek M Badr; Robert G Stout; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2007-10-17       Impact factor: 2.502

Review 5.  [Evidence-based intensive care medicine. Practice, use and significance].

Authors:  J Graf; U Janssens
Journal:  Anaesthesist       Date:  2004-03       Impact factor: 1.041

6.  Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring.

Authors:  Sophie Marqué; Alain Cariou; Jean-Daniel Chiche; Pierre Squara
Journal:  Crit Care       Date:  2009-05-19       Impact factor: 9.097