Optimal side plate fixation for unstable intertrochanteric hip fractures.

E H Yian1, I Banerji, L S Matthews.   

Abstract

OBJECTIVES: To quantitatively determine the minimal screw number needed for stable side plate fixation to the femoral shaft in treating unstable intertrochanteric hip fractures.
DESIGN: Laboratory/biomedics study.
SETTING: Orthopaedic biomechanics laboratory. PATIENTS OR OTHER PARTICIPANTS: The convenience sample was made up of one saw bone, one steel pipe, and ten human cadaveric femur specimens. Human specimens were selected by ruling out pathology and excess osteopenia. Ten specimens were tested to completion. INTERVENTION: Telescoping hip screw and hip screw side plate secured with various numbered combinations of side plate screws. MAIN OUTCOME MEASURES: Decreases in tension experienced by all previously inserted screws when an additional screw was applied were recorded and labeled as "protection."
RESULTS: Protection offered by a third screw on all previous screws was 787.3 newtons in the steel pipemodel, 71.2 newtons in the sawbone model, and 158.3 newtons in the human model (p < 0.005). A fourth bone screw did not decrease tension in previous screws by more than 11 newtons. The protective effect of the fourth screw on screw #3 increased with decreasing screw application torque by a maximum of 21.8 newtons (p < 0.005).
CONCLUSION: This study suggests that three bone screws provide an optimal distribution of tensile forces. The insertional torque used to place screws, once screw-plate contact has been established, does not play a significant role in screw protection. Additional studies are needed to assess the role of cortical bone density, and cyclical loading and bending forces experienced by the side plate screws, before definite clinical recommendations can be made.

Entities:  

Mesh:

Year:  1997        PMID: 9258822     DOI: 10.1097/00005131-199705000-00003

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  6 in total

1.  Comparison of stable and unstable pertrochanteric femur fractures managed with 2- and 4-hole side plates.

Authors:  Robert P Baird; Peter O'Brien; David Cruickshank
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

2.  Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods.

Authors:  Yih-Shiunn Lee; Hui-Ling Huang; Ting-Ying Lo; Chien-Rae Huang
Journal:  Int Orthop       Date:  2006-10-12       Impact factor: 3.075

3.  A comparative Study of Novel Extramedullary Fixation and Dynamic Hip Screw in the Fixation of Intertrochanteric Fracture: A Finite-Element Analysis.

Authors:  Kai Ding; Yanbin Zhu; Haicheng Wang; Yonglong Li; Weijie Yang; Xiaodong Cheng; Yingze Zhang; Wei Chen; Qi Zhang
Journal:  Front Surg       Date:  2022-05-25

4.  Internal fixation of pertrochanteric fractures using DHS with a two-hole side-plate.

Authors:  Daniel Ríha; Jan Bartonícek
Journal:  Int Orthop       Date:  2010-08       Impact factor: 3.075

Review 5.  Dynamic Hip Screw Plate Length in Stable Intertrochanteric Fracture Neck of Femur: A Systematic Review.

Authors:  Aditya Soni; Sandeep Munshi; Niranj G Radhamony; Rajiv Nair; Sachith Sreenivasan
Journal:  Cureus       Date:  2022-03-14

6.  Minimal Invasive Dynamic Hip Screw Fixation Technique in Patient with Cardiac Complications: A Case Scenario.

Authors:  Ponnusami Pillai Gokulakrishnan; Anil Gowtham Manivannan; Sakthivel Annamalai; Balaji Umamaheshwaran
Journal:  J Orthop Case Rep       Date:  2017 Sep-Oct
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.