Literature DB >> 9255823

Repeatability and accuracy of automated refraction: a comparison of the Nikon NRK-8000, the Nidek AR-1000, and subjective refraction.

M Elliott1, T Simpson, D Richter, D Fonn.   

Abstract

This study assessed the repeatability of the Nikon NRK-8000, the Nidek AR-1000, and subjective refraction. In addition, the accuracy of the Nikon and the Nidek were evaluated in comparison to subjective refraction. Measurements were taken with all 3 techniques on 2 separate occasions with a test-retest separation of at least 24 h. The right eyes of 30 normal subjects were used. Repeatability and accuracy statistics and plots were generated using matrix representations of dioptric power. Subjective refraction was the most repeatable method, with the coefficient of repeatability (COR) found to be 0.611, 0.224, and 0.490 in the vertical, torsional, and horizontal meridians. The autorefractors' COR was found to range from 0.712 to 0.826 for the vertical and horizontal meridians, whereas the torsional meridian ranged from 0.224 to 0.319.

Mesh:

Year:  1997        PMID: 9255823     DOI: 10.1097/00006324-199706000-00028

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  10 in total

1.  [Agreement of subjective and objective refraction measurements following INTRACOR femtosecond laser treatment].

Authors:  A Fitting; A Ehmer; T M Rabsilber; G U Auffarth; M P Holzer
Journal:  Ophthalmologe       Date:  2011-09       Impact factor: 1.059

2.  The myopic shift associated with hyperbaric oxygen administration is reduced when using a mask delivery system compared to a hood - a randomised controlled trial.

Authors:  Michael H Bennett; Cheng Fb Hui; Hooi G See; Kwan L Au-Yeung; Christopher Tan; Stephanie Watson
Journal:  Diving Hyperb Med       Date:  2019-12-20       Impact factor: 0.887

3.  Comparison of refractive assessment by wavefront aberrometry, autorefraction, and subjective refraction.

Authors:  Jeffrey R Bennett; Gina M Stalboerger; David O Hodge; Muriel M Schornack
Journal:  J Optom       Date:  2014-12-11

4.  Vision screening at two years does not reduce the prevalence of reduced vision at four and a half years of age.

Authors:  Lucy Goodman; Arijit Chakraborty; Nabin Paudel; Tzu-Ying Yu; Robert J Jacobs; Jane E Harding; Benjamin Thompson; Nicola S Anstice
Journal:  Clin Exp Optom       Date:  2017-11-28       Impact factor: 2.742

5.  Image Quality Metric Derived Refractions Predicted to Improve Visual Acuity Beyond Habitual Refraction for Patients With Down Syndrome.

Authors:  Ayeswarya Ravikumar; Julia S Benoit; Jason D Marsack; Heather A Anderson
Journal:  Transl Vis Sci Technol       Date:  2019-05-20       Impact factor: 3.283

6.  Steps towards Smarter Solutions in Optometry and Ophthalmology-Inter-Device Agreement of Subjective Methods to Assess the Refractive Errors of the Eye.

Authors:  Arne Ohlendorf; Alexander Leube; Siegfried Wahl
Journal:  Healthcare (Basel)       Date:  2016-07-13

7.  Spherical subjective refraction with a novel 3D virtual reality based system.

Authors:  Jaume Pujol; Juan Carlos Ondategui-Parra; Llorenç Badiella; Carles Otero; Meritxell Vilaseca; Mikel Aldaba
Journal:  J Optom       Date:  2016-02-05

8.  Stabilization of refractive error and associated factors following small incision phacoemulsification cataract surgery.

Authors:  Ammar M Khan; Derek M Waldner; Micah Luong; Emi Sanders; Andrew C S Crichton; Bryce A Ford
Journal:  BMC Ophthalmol       Date:  2022-01-06       Impact factor: 2.209

9.  Short-term stability in refractive status despite large fluctuations in glucose levels in diabetes mellitus type 1 and 2.

Authors:  Byki Huntjens; W Neil Charman; Helena Workman; Sarah L Hosking; Clare O'Donnell
Journal:  PLoS One       Date:  2012-12-28       Impact factor: 3.240

10.  Agreement and Repeatability of Central and Peripheral Refraction by One Novel Multispectral-Based Refractor.

Authors:  Weicong Lu; Rongyuan Ji; Wenzhi Ding; Yuyin Tian; Keli Long; Zhen Guo; Lin Leng
Journal:  Front Med (Lausanne)       Date:  2021-12-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.