Literature DB >> 9253999

Analysis of tracer transit in rat brain after carotid artery and femoral vein administrations using linear system theory.

M Rudin1, N Beckmann, A Sauter.   

Abstract

Determination of tissue perfusion rates by MRI bolus tracking methods relies on the central volume principle which states that tissue blood flow is given by the tissue blood volume divided by the mean tracer transit time (MTT). Accurate determination of the MTT requires knowledge of the arterial input function which in MRI experiments is usually not known, especially when using small animals. The problem of unknown arterial input can be circumvented in animal experiments by directly injecting the contrast agent into a feeding artery of the tissue of interest. In the present article the passage of magnetite nanoparticles through the rat cerebral cortex is analyzed after injection into the internal carotid artery. The results are discussed in the framework of linear system theory using a one-compartment model for brain tissue and by using the well characterized gamma-variate function to describe the tissue concentration profile of the contrast agent. The results obtained from the intra-arterial tracer administration experiments are then compared with the commonly used intra-venous injection of the contrast agent in order to estimate the contribution of the peripheral circulation to the MTT values in the latter case. The experiments were analyzed using a two-compartment model and the gamma-variate function. As an application perfusion rates in normal and ischemic cerebral cortex of hypertensive rats were estimated in a model of focal cerebral ischemia. The results indicate that peripheral circulation has a significant influence on the MTT values and thus on the perfusion rates, which cannot be neglected.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9253999     DOI: 10.1016/s0730-725x(97)00016-7

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  2 in total

1.  Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

Authors:  Xiaoliang Zhang; Xiao-Hong Zhu; Runxia Tian; Yi Zhang; Hellmut Merkle; Wei Chen
Journal:  MAGMA       Date:  2003-07-04       Impact factor: 2.310

2.  Hemodynamic nonlinearities affect BOLD fMRI response timing and amplitude.

Authors:  Jacco A de Zwart; Peter van Gelderen; J Martijn Jansma; Masaki Fukunaga; Marta Bianciardi; Jeff H Duyn
Journal:  Neuroimage       Date:  2009-06-08       Impact factor: 6.556

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.