Literature DB >> 9246864

High-pass filtering of the electrogastrogram.

I Daskalov1, I Christov, V Kolev.   

Abstract

The recording and processing of an electrogastrogram require adequate band-pass filtering, to suppress unwanted artefacts but preserve the original signal waveform. High-pass filtering of various types, of different time constants tau, filter order, analogue and digital implementation, have been used to obtain higher baseline stability and faster signal recovery after strong artefacts. Special attention should be given to possible signal amplitude and phase distortions due to high-pass filtering, which can strongly influence accurate amplitude measurements or studies of signal propagation from multichannel recordings. Synthesised and original signals are used to demonstrate the effect of high-pass filtering. The use of a first-order filter with tau = 5 s is recommended for EGG studies if not especially directed to investigation of bradygastria. In the opposite case, tau = 15 s should be used, and with backward filtering a full restoration of the original signal can be obtained. The same is valid for recording the electrical activity of the colon. Lower time constants (tau = 5 s or less) can be applied to acquire signals from the small intestines. A radical solution is the use of a DC amplifier with controllable subtraction of the DC component.

Mesh:

Year:  1997        PMID: 9246864     DOI: 10.1007/bf02530050

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  9 in total

1.  [Recording of data and immediate interpretation of myoelectric activity of the stomach--electrogastrography].

Authors:  C Coenen; M Theus; U Theus
Journal:  Biomed Tech (Berl)       Date:  1992-05       Impact factor: 1.411

2.  Bedside system for cutaneous recording and analysis of gastric myoelectrical and impedance signals.

Authors:  P P Bruijs; E J van der Schee; A J Smout; L M Akkermans; H L van Strien
Journal:  Med Biol Eng Comput       Date:  1991-11       Impact factor: 2.602

Review 3.  Electrogastrography: measurement, analysis and prospective applications.

Authors:  J Chen; R W McCallum
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

4.  Multichannel DC amplifier for a microprocessor electroencephalograph.

Authors:  I A Dotsinsky; I I Christov; I K Daskalov
Journal:  Med Biol Eng Comput       Date:  1991-05       Impact factor: 2.602

Review 5.  Electrogastrography. Current assessment and future perspectives.

Authors:  T L Abell; J R Malagelada
Journal:  Dig Dis Sci       Date:  1988-08       Impact factor: 3.199

6.  Frequency components of the electrogastrogram and their correlations with gastrointestinal contractions in humans.

Authors:  J Chen; R W McCallum; R Richards
Journal:  Med Biol Eng Comput       Date:  1993-01       Impact factor: 2.602

7.  Time-frequency representation of the electrogastrogram--application of the exponential distribution.

Authors:  Z Y Lin; J D Chen
Journal:  IEEE Trans Biomed Eng       Date:  1994-03       Impact factor: 4.538

8.  Response of the electric activity in the human stomach to water and a solid meal.

Authors:  J Chen; R W McCallum
Journal:  Med Biol Eng Comput       Date:  1991-07       Impact factor: 2.602

9.  Non-invasive electrogastrography. Part 2. Human electrogastrogram.

Authors:  E Atanassova; I Daskalov; I Dotsinsky; I Christov; A Atanassova
Journal:  Arch Physiol Biochem       Date:  1995-08       Impact factor: 4.076

  9 in total