Literature DB >> 9245904

Autoregulation of human optic nerve head circulation in response to increased intraocular pressure.

L E Pillunat1, D R Anderson, R W Knighton, K M Joos, W J Feuer.   

Abstract

The following experiments were undertaken to determine if blood flow is maintained by autoregulation in the human optic nerve head when circulation is challenged by elevated intraocular pressure, and to determine if the presence or absence of autoregulation is universal. Laser Doppler flowmetry was used to determine the average velocity, the number of moving erythrocytes, and the volume of flow in the capillary bed of the optic disc. These parameters were measured in 10 subjects at spontaneous levels of intraocular pressure (IOP), and at pressures artificially elevated to 25, 35, 45 and 55 mm Hg with a scleral suction cup. Four subjects (two who showed autoregulation and two who did not) were studied on six additional occasions to determine consistency of the findings. In these same four subjects a second location on the disc was also measured on six occasions to determine if the IOP-effect on blood flow varied by location. Of the 10 subjects initially studied, seven maintained the baseline level of blood flow over the lower part of the range of elevated intraocular pressure (evidence of autoregulation), but showed a decline in flow by the time IOP reached 45 or 55 mm Hg. Two subjects showed a linear decline in blood flow beginning with the smallest increment of elevation of IOP (no autoregulation), and one showed an uninterpretable result. The two individuals who showed the linear decline and two of those who showed efficient autoregulation were remeasured, and each showed consistently the same pattern as before when restudied on six different occasions each. However, at a different location on their discs, autoregulation was manifest in all of these four individuals. When challenged by elevated IOP, the optic nerve head typically maintains a steady-blood flow over a range of IOP, but fails to maintain the same flow by the time IOP reaches 45 or 55 mm Hg. Some disc locations, at least in some individuals, do not show this autoregulation, but exhibit a decline in blood flow linearly related to IOP, even with the modest elevation of IOP.

Entities:  

Mesh:

Year:  1997        PMID: 9245904     DOI: 10.1006/exer.1996.0263

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  46 in total

1.  Effect of acute intraocular pressure changes on short posterior ciliary artery haemodynamics.

Authors:  K M Joos; M D Kay; L E Pillunat; A Harris; E K Gendron; W J Feuer; B E Steinwand
Journal:  Br J Ophthalmol       Date:  1999-01       Impact factor: 4.638

Review 2.  Basic principles of laser Doppler flowmetry and application to the ocular circulation.

Authors:  C E Riva
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

3.  Autoregulative behavior of retinal arteries and veins during changes of perfusion pressure: a clinical study.

Authors:  Edgar Nagel; Walthard Vilser
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-11-25       Impact factor: 3.117

Review 4.  [Characteristic features of optic nerve ganglion cells and approaches for neuroprotection. From intracellular to capillary processes and therapeutic considerations].

Authors:  R H W Funk; K-G Schmidt
Journal:  Ophthalmologe       Date:  2004-11       Impact factor: 1.059

5.  Habituation of retinal ganglion cell activity in response to steady state pattern visual stimuli in normal subjects.

Authors:  Vittorio Porciatti; Nancy Sorokac; William Buchser
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-04       Impact factor: 4.799

6.  Regulation of optic nerve head blood flow during combined changes in intraocular pressure and arterial blood pressure.

Authors:  Agnes Boltz; Doreen Schmidl; René M Werkmeister; Michael Lasta; Semira Kaya; Stefan Palkovits; Reinhard Told; Katarzyna J Napora; Alina Popa-Cherecheanu; Gerhard Garhöfer; Leopold Schmetterer
Journal:  J Cereb Blood Flow Metab       Date:  2013-08-07       Impact factor: 6.200

Review 7.  Perioperative visual loss: what do we know, what can we do?

Authors:  S Roth
Journal:  Br J Anaesth       Date:  2009-12       Impact factor: 9.166

8.  Does steep Trendelenburg positioning effect the ocular hemodynamics and intraocular pressure in patients undergoing robotic cystectomy and robotic prostatectomy?

Authors:  Muhammet Fuat Ozcan; Ziya Akbulut; Canan Gurdal; Sinan Tan; Yelda Yildiz; Serdar Bayraktar; Ayse Nur Ozcan; Kemal Ener; Serkan Altinova; Muhammed Ersagun Arslan; Mevlana Derya Balbay
Journal:  Int Urol Nephrol       Date:  2016-11-01       Impact factor: 2.370

Review 9.  Effects of optic nerve injury, glaucoma, and neuroprotection on the survival, structure, and function of ganglion cells in the mammalian retina.

Authors:  A J Weber; C D Harman; S Viswanathan
Journal:  J Physiol       Date:  2008-06-19       Impact factor: 5.182

10.  The effect of latanoprost on ocular blood flow.

Authors:  Alon Harris; Hanna J Garzozi; Lynne McCranor; Ehud Rechtman; Chi-Wah Yung; Brent Siesky
Journal:  Int Ophthalmol       Date:  2008-02-23       Impact factor: 2.031

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.