The apical long-axis rather than the two-chamber view should be used in combination with the four-chamber view for accurate assessment of left ventricular volumes and function.

Y F Nosir1, W B Vletter, E Boersma, R Frowijn, F J Ten Cate, P M Fioretti, J R Roelandt.   

Abstract

BACKGROUND: Most biplane methods for the echocardiographic calculation of left ventricular volumes assume orthogonality between paired views from the apical window. Our aim was to study the accuracy of biplane left ventricular volume calculations when either the apical two-chamber or long-axis views are combined with the four-chamber view. The left ventricular volumes calculated from three-dimensional echocardiographic data sets were used as a reference. Twenty-seven patients underwent precordial three-dimensional echocardiography using rotational acquisition of planes at 2-degree intervals, with ECG and respiratory gating. End-diastolic and end-systolic left ventricular volumes and ejection fraction on three-dimensional echocardiography were calculated by (1) Simpson's methods (3DS) at 3 mm short-axis slice thickness (reference method) and by (2) biplane ellipse from paired views using either apical four- and two-chamber views (BE-A) or apical four- and long-axis views (BE-B). Observer variabilities were studied by the standard error of the estimate % (SEE) in 19 patients for all methods.
RESULTS: The spatial angles (mean +/- SD) between the apical two-chamber, long-axis and four-chamber views were 63.3 degrees +/- 19.7 and 99.1 degrees +/- 25.6, respectively. The mean +/- SD of end-diastolic and end-systolic left ventricular volumes (ml) and ejection fraction (%) by 3DS were 142.2 +/- 60.9, 91.8 +/- 59.6 and 39.6 +/- 17.5, while that by BE-A were 126.7 +/- 60.4, 84.0 +/- 57.9 and 39 +/- 17 and by BE-B were 134.3 +/- 62.4, 88.6 +/- 59.7 and 39.1 +/- 16.7, respectively. BE-B intra-observer (8.4, 6.7 and 3.5) and inter-observer (9.8, 11.5 and 5.4) SEE for end-diastolic and end-systolic left ventricular volumes (ml) and ejection fraction (%), respectively, were smaller than that for BE-A (10.8, 8.8 and 4.1 and 11.4, 14.7 and 6.1, respectively). There was excellent correlation between 3DS and BE-A (r = 0.99, 0.98 and 0.98) and BE-B (0.98, 0.98 and 0.98) for calculating end-diastolic and end-systolic left ventricular volume and ejection fractions, respectively. There were no significant differences between BE-A and BE-B with 3DS for end-diastolic and end-systolic left ventricular volume and ejection fraction calculations (P = 0.2, 0.3 and 0.4 and P = 0.5, 0.5 and 0.4, respectively). There were closer limits of agreement (mean +/- 2 SD) between 3DS and BE-B 7.9 +/- 18.8, 3.2 +/- 14.2 and 0.8 +/- 5.8 than that between 3DS and BE-A 15.5 +/- 19.6, 7.8 +/- 16.2 and 1.1 +/- 7.4 for calculating end-diastolic and end-systolic left ventricular volume and ejection fractions, respectively.
CONCLUSION: Both apical two-chamber and apical long-axis views are not orthogonal to the apical four-chamber view. Observer variabilities of BE-B were smaller than that for BE-A. BE-A and BE-B have excellent correlation and non-significant differences with 3DS for left ventricular volume and ejection fraction calculations. There were closer limits of agreement between BE-B with 3DS for left ventricular volume and ejection fraction calculations than that between BE-A and 3DS. Therefore, we recommend the use of the apical long-axis rather than the two-chamber view in combination with the four-chamber view for accurate biplane left ventricular volume and ejection fraction calculations.

Entities:  

Mesh:

Year:  1997        PMID: 9243153     DOI: 10.1093/oxfordjournals.eurheartj.a015414

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  10 in total

1.  Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial borders.

Authors:  Donato Mele; Roberta Teoli; Corrado Cittanti; Giovanni Pasanisi; Gabriele Guardigli; Robert A Levine; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

2.  [Quality assurance in echocardiography. Three-level system in formation and qualifying and concept of an external quality review].

Authors:  W Fehske; T Buck; A Hagendorff; R S von Bardeleben; W Voelker; S Heinemann
Journal:  Z Kardiol       Date:  2005-01

3.  The relationship between cardiac output and dynamic cerebral autoregulation in humans.

Authors:  B M Deegan; E R Devine; M C Geraghty; E Jones; G Ólaighin; J M Serrador
Journal:  J Appl Physiol (1985)       Date:  2010-08-05

4.  Prospective echocardiography assessment of pulmonary hypertension and its potential etiologies in children with sickle cell disease.

Authors:  Niti Dham; Gregory Ensing; Caterina Minniti; Andrew Campbell; Manuel Arteta; Sohail Rana; Deepika Darbari; Mehdi Nouraie; Onyinye Onyekwere; Malgorzata Lasota; Gregory J Kato; Mark T Gladwin; Oswaldo Castro; Victor Gordeuk; Craig Sable
Journal:  Am J Cardiol       Date:  2009-06-24       Impact factor: 2.778

5.  5/6 Area length method for left-ventricular ejection-fraction measurement in adults with repaired tetralogy of Fallot: comparison with cardiovascular magnetic resonance.

Authors:  Jimmy C Lu; Gregory J Ensing; Sunkyung Yu; Thor Thorsson; Janet E Donohue; Adam L Dorfman
Journal:  Pediatr Cardiol       Date:  2012-07-14       Impact factor: 1.655

6.  Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs.

Authors:  Haitham Ballo; Miikka Tarkia; Matti Haavisto; Christoffer Stark; Marjatta Strandberg; Tommi Vähäsilta; Virva Saunavaara; Tuula Tolvanen; Mika Teräs; Ville-Veikko Hynninen; Timo Savunen; Anne Roivainen; Juhani Knuuti; Antti Saraste
Journal:  Cardiovasc Ultrasound       Date:  2017-01-09       Impact factor: 2.062

7.  Contrast Enhancement and Image Quality Influence Two- and Three-dimensional Echocardiographic Determination of Left Ventricular Volumes: Comparison With Magnetic Resonance Imaging.

Authors:  Jonas Jenner; Peder Sörensson; John Pernow; Kenneth Caidahl; Maria J Eriksson
Journal:  Clin Med Insights Cardiol       Date:  2019-03-05

8.  Machine learning algorithm using publicly available echo database for simplified "visual estimation" of left ventricular ejection fraction.

Authors:  Michael Blaivas; Laura Blaivas
Journal:  World J Exp Med       Date:  2022-03-20

9.  Rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating heart failure from pulmonary disease as the cause of acute dyspnea in the emergency setting.

Authors:  Katsuya Kajimoto; Keiko Madeen; Tomoko Nakayama; Hiroki Tsudo; Tadahide Kuroda; Takashi Abe
Journal:  Cardiovasc Ultrasound       Date:  2012-12-04       Impact factor: 2.062

10.  Supernormal functional reserve of apical segments in elite soccer players: an ultrasound speckle tracking handgrip stress study.

Authors:  Laura Stefani; Loira Toncelli; Valentina Di Tante; Maria Concetta Roberta Vono; Brunello Cappelli; Gianni Pedrizzetti; Giorgio Galanti
Journal:  Cardiovasc Ultrasound       Date:  2008-04-16       Impact factor: 2.062