Literature DB >> 9236983

Technical features of a CCD video camera system to record cardiac fluorescence data.

W T Baxter1, J M Davidenko, L M Loew, J P Wuskell, J Jalife.   

Abstract

A charge-coupled device (CCD) camera was used to acquire movies of transmembrane activity from thin slices of sheep ventricular epicardial muscle stained with a voltage-sensitive dye. Compared with photodiodes, CCDs have high spatial resolution, but low temporal resolution. Spatial resolution in our system ranged from 0.04 to 0.14 mm/pixel; the acquisition rate was 60, 120, or 240 frames/sec. Propagating waves were readily visualized after subtraction of a background image. The optical signal had an amplitude of 1 to 6 gray levels, with signal-to-noise ratios between 1.5 and 4.4. Because CCD cameras integrate light over the frame interval, moving objects, including propagating waves, are blurred in the resulting movies. A computer model of such an integrating imaging system was developed to study the effects of blur, noise, filtering, and quantization on the ability to measure conduction velocity and action potential duration (APD). The model indicated that blurring, filtering, and quantization do not affect the ability to localize wave fronts in the optical data (i.e., no systematic error in determining spatial position), but noise does increase the uncertainty of the measurements. The model also showed that the low frame rates of the CCD camera introduced a systematic error in the calculation of APD: for cutoff levels > 50%, the APD was erroneously long. Both noise and quantization increased the uncertainty in the APD measurements. The optical measures of conduction velocity were not significantly different from those measured simultaneously with microelectrodes. Optical APDs, however, were longer than the electrically recorded APDs. This APD error could be reduced by using the 50% cutoff level and the fastest frame rate possible.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9236983     DOI: 10.1007/bf02684848

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  11 in total

1.  Visualizing excitation waves inside cardiac muscle using transillumination.

Authors:  W T Baxter; S F Mironov; A V Zaitsev; J Jalife; A M Pertsov
Journal:  Biophys J       Date:  2001-01       Impact factor: 4.033

2.  Intramural multisite recording of transmembrane potential in the heart.

Authors:  D A Hooks; I J LeGrice; J D Harvey; B H Smaill
Journal:  Biophys J       Date:  2001-11       Impact factor: 4.033

3.  Examination of optical depth effects on fluorescence imaging of cardiac propagation.

Authors:  Mark-Anthony Bray; John P Wikswo
Journal:  Biophys J       Date:  2003-12       Impact factor: 4.033

4.  Synthesis of voltage-sensitive fluorescence signals from three-dimensional myocardial activation patterns.

Authors:  Christopher J Hyatt; Sergey F Mironov; Marcel Wellner; Omer Berenfeld; Alois K Popp; David A Weitz; José Jalife; Arkady M Pertsov
Journal:  Biophys J       Date:  2003-10       Impact factor: 4.033

5.  In vitro functional imaging in brain slices using fast voltage-sensitive dye imaging combined with whole-cell patch recording.

Authors:  Greg C Carlson; Douglas A Coulter
Journal:  Nat Protoc       Date:  2008       Impact factor: 13.491

6.  Extracting intramural wavefront orientation from optical upstroke shapes in whole hearts.

Authors:  Christian W Zemlin; Olivier Bernus; Arvydas Matiukas; Christopher J Hyatt; Arkady M Pertsov
Journal:  Biophys J       Date:  2008-04-04       Impact factor: 4.033

Review 7.  Toward microendoscopy-inspired cardiac optogenetics in vivo: technical overview and perspective.

Authors:  Aleksandra Klimas; Emilia Entcheva
Journal:  J Biomed Opt       Date:  2014-08       Impact factor: 3.170

Review 8.  Optical brain imaging in vivo: techniques and applications from animal to man.

Authors:  Elizabeth M C Hillman
Journal:  J Biomed Opt       Date:  2007 Sep-Oct       Impact factor: 3.170

9.  Basic concepts of optical mapping techniques in cardiac electrophysiology.

Authors:  Mina Attin; William T Clusin
Journal:  Biol Res Nurs       Date:  2009-07-17       Impact factor: 2.522

10.  Endoscopic fluorescence mapping of the left atrium: a novel experimental approach for high resolution endocardial mapping in the intact heart.

Authors:  Jérôme Kalifa; Matthew Klos; Sharon Zlochiver; Sergey Mironov; Kazuhiko Tanaka; Netha Ulahannan; Masatoshi Yamazaki; José Jalife; Omer Berenfeld
Journal:  Heart Rhythm       Date:  2007-03-15       Impact factor: 6.343

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.