Literature DB >> 9234976

The effects of time and light exposure on contact and pressure measurements using Fuji prescale film.

R Patterson1, D Pogue, S Viegas.   

Abstract

The search for methods to demonstrate and accurately measure contact area and pressure within human joints has been and remains an active one. Presenssor is a measuring system developed by Fuji Photo Film Co., Ltd. and used in medical applications. The color intensity fades with time and exposure to light. These changes have not been well documented despite the increasing use of Fuji film in biomedical research. These changes in color intensity provide a source of error in the calculated measurements. The known variability of the color density of film exposed to light and air can be measured and predicted. Methods to control and improve the accuracy and reliability of study data are suggested. Film was exposed to three different amounts of pressure and placed into one of four subgroups: exposed to light and taped or not taped, and stored in the dark and taped or not taped. Fading of the color density was seen after only a few hours of exposure to light when the film was left untaped. When the film was taped, a slight darkening was seen. For the best accuracy and reliability, the film should be digitized or analyzed within eight hours of exposure to pressure.

Entities:  

Mesh:

Year:  1997        PMID: 9234976      PMCID: PMC2378119     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  4 in total

1.  Contact stress gradient detection limits of Pressensor film.

Authors:  J E Hale; T D Brown
Journal:  J Biomech Eng       Date:  1992-08       Impact factor: 2.097

2.  Force distribution across wrist joint: application of pressure-sensitive conductive rubber.

Authors:  T Hara; E Horii; K N An; W P Cooney; R L Linscheid; E Y Chao
Journal:  J Hand Surg Am       Date:  1992-03       Impact factor: 2.230

3.  The effects of various load paths and different loads on the load transfer characteristics of the wrist.

Authors:  S F Viegas; R Patterson; P Peterson; J Roefs; A Tencer; S Choi
Journal:  J Hand Surg Am       Date:  1989-05       Impact factor: 2.230

4.  [Intra-articular pressure measurement. A new method for the use of the pressure measuring film "Prescale"].

Authors:  B Rieck; O Paar; P Bernett
Journal:  Z Orthop Ihre Grenzgeb       Date:  1984 Nov-Dec
  4 in total
  1 in total

1.  The Usability of a Pressure-Indicating Film to Measure the Teat Load Caused by a Collapsing Liner.

Authors:  Susanne Demba; Sabrina Elsholz; Christian Ammon; Sandra Rose-Meierhöfer
Journal:  Sensors (Basel)       Date:  2016-09-28       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.