Literature DB >> 9233093

Incidence of visible and occult blood on laryngoscope blades and handles.

R A Phillips1, W P Monaghan.   

Abstract

Anesthesia providers must take appropriate precautions to reduce the potential for transmission of infectious agents to the patients under their care. The devastating spread of human immunodeficiency virus (HIV) and hepatitis B virus (HBV) over the past decade has resulted in the development of specific guidelines for the cleaning, disinfection, sterilization, and handling of medical equipment and instruments. Contamination of laryngoscope blades and handles with visible and occult blood frequently occurs during routine airway management. Several studies suggest procedures for cleaning, disinfection, sterilization, or handling of laryngoscope blades and handles are ineffective, or there may be poor compliance with the established protocols. The purpose of this study was to determine the incidence of visible and occult blood on laryngoscope blades and handles that were identified as ready for patient use. Sixty-five laryngoscope blades and handles identified as ready for patient use were observed for visible blood and tested for occult blood. A modified version of the three-stage phenolphthalein blood indicator test was employed to determine the presence of occult blood. None of the blades or handles observed had visible blood. Of the 65 blades tested for occult blood, 13 (20%) tested positive. Of the 65 handles tested for occult blood, 26 (40%) tested positive. More afternoon blades and handles tested positive for occult blood than morning blades and handles (P < 0.01). The extent to which contaminated anesthesia equipment plays in nosocomial infection is difficult to determine. The presence of blood is an indicator of potential cross-infection, since biological fluids, such as blood and saliva, are known to transmit infectious diseases. This study confirms that more rigorous decontamination protocols must be instituted to ensure complete removal of blood prior to sterilization, since laryngoscope blades and handles have irregular surfaces with repositories for infectious material.

Entities:  

Mesh:

Year:  1997        PMID: 9233093

Source DB:  PubMed          Journal:  AANA J        ISSN: 0094-6354


  7 in total

1.  Nosocomial contamination of laryngoscope handles: challenging current guidelines.

Authors:  Tyler R Call; Frederic J Auerbach; Scott W Riddell; Deanna L Kiska; Sumena C Thongrod; See Wan Tham; Nancy A Nussmeier
Journal:  Anesth Analg       Date:  2009-08       Impact factor: 5.108

2.  Recommended practices for cleaning, handling and processing anesthesia equipment.

Authors: 
Journal:  AORN J       Date:  2005-04       Impact factor: 0.676

3.  Infection control in anaesthesia.

Authors: 
Journal:  Anaesthesia       Date:  2008-09       Impact factor: 6.955

4.  Anaesthetic considerations for the hiv positive parturient.

Authors:  Adesina Oluwabukola; Oladokun Adesina
Journal:  Ann Ib Postgrad Med       Date:  2009-06

5.  Comparison of Glidescope® Go™, King Vision™, Dahlhausen VL, I‑View™ and Macintosh laryngoscope use during difficult airway management simulation by experienced and inexperienced emergency medical staff: A randomized crossover manikin study.

Authors:  Andreas Moritz; Veronika Leonhardt; Johannes Prottengeier; Torsten Birkholz; Joachim Schmidt; Andrea Irouschek
Journal:  PLoS One       Date:  2020-07-30       Impact factor: 3.240

6.  Pattern of anaesthetic equipment contamination and infection prevention in anaesthesia practice at university hospitals.

Authors:  Rehab M Elsaid Tash; Ahmed A Wegdan; Fatma A Amer; Rasha H A Bassyouni; Joseph M Botros
Journal:  Indian J Anaesth       Date:  2018-10

Review 7.  Disinfection and Sterilization in Health Care Facilities: An Overview and Current Issues.

Authors:  William A Rutala; David J Weber
Journal:  Infect Dis Clin North Am       Date:  2016-09       Impact factor: 5.982

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.