Literature DB >> 9232569

Sonography of transjugular intrahepatic portosystemic shunts: detection of elevated portosystemic gradients and loss of shunt function.

Z J Haskal1, J W Carroll, J E Jacobs, P H Arger, D Yin, B G Coleman, J E Langer, S E Rowling, H L Nisenbaum.   

Abstract

PURPOSE: To evaluate the role of ultrasound (US) in the detection of elevated portosystemic gradients and loss of shunt function in patients with a transjugular intrahepatic portosystemic shunt (TIPS).
MATERIALS AND METHODS: The authors' prospectively compared 151 Doppler hepatic sonograms with follow-up portal venograms in 64 patients with TIPS. Sonographic data from within the portal system, hepatic arteries, and three areas within the TIPS were collected. Statistical analysis of these parameters was used to establish the US criteria for shunt dysfunction.
RESULTS: Midshunt velocity thresholds of less than 50 and less than 60 cm/sec yielded sensitivities and specificities of 46% and 93%, and 57% and 89%, respectively, for the detection of portosystemic gradients exceeding 15 mm Hg. Use of a threshold midshunt velocity of less than 60 cm/sec or main portal vein velocity of less than 40 cm/sec raised the shunt dysfunction detection sensitivity to 86%, with a specificity of 54%.
CONCLUSION: Doppler US is an effective noninvasive screening tool for detecting elevated portosystemic gradients and evaluating the functional status of a TIPS. Midshunt velocities of less than 60 cm/sec or main portal vein velocities less than 40 cm/sec are a useful threshold for detecting shunt dysfunction.

Entities:  

Mesh:

Year:  1997        PMID: 9232569     DOI: 10.1016/s1051-0443(97)70607-9

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

1.  Retrospective evaluation of early thrombosis in transjugular intrahepatic portosystemic polytetrafluoroethylene-coated shunts under 2-day postinterventional heparinization.

Authors:  Holger Goessmann; Verna Schuffenhauer; Arne Kandulski; Kilian Weigand; Ernst-Michael Jung; Wibke Uller; Gregor Scharf; Cristian Stroszczynski; Niklas Verloh
Journal:  Sci Rep       Date:  2022-06-22       Impact factor: 4.996

2.  Efficacy of TACE in TIPS patients: comparison of treatment response to chemoembolization for hepatocellular carcinoma in patients with and without a transjugular intrahepatic portosystemic shunt.

Authors:  Yuo-Chen Kuo; Maureen P Kohi; David M Naeger; Ricky T Tong; K Pallav Kolli; Andrew G Taylor; Jeanne M Laberge; Robert K Kerlan; Nicholas Fidelman
Journal:  Cardiovasc Intervent Radiol       Date:  2013-07-18       Impact factor: 2.740

3.  Is color-Doppler US a reliable method in the follow-up of transjugular intrahepatic portosystemic shunt (TIPS)?

Authors:  P Ricci; V Cantisani; V Lombardi; G Alfano; U D'Ambrosio; G Menichini; E Marotta; F M Drudi
Journal:  J Ultrasound       Date:  2007-04-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.