Literature DB >> 923064

Echocardiographic study of cardiac tamponade.

H P Settle, R J Adolph, N O Fowler, P Engel, N S Agruss, N I Levenson.   

Abstract

We studied 14 patients with cardiac tamponade and pulsus paradoxus; 11 were studied after relief of tamponade by pericardiocentesis. Right ventricle diastolic diameter increased during inspiration in each of 12 patients; left ventricle diastolic diameter decreased during inspiration in each of 13. Mitral valve DE amplitude decreased with inspiration in 13 of 14 patients. Mitral valve E-F slope could be measured in eight patients, and was rounded and not measurable in six. Six of the eight showed inspiratory decrease in mitral E-F slope. Similar changes were observed in two other patients with pulsus paradoxus who had chronic obstructive airway disease. Twenty patients with large pericardial effusions and no tamponade did not show these changes. These results suggest inspiratory augmentation of right ventricular filling and inspiratory diminution of left ventricular filling, not only in cardiac tamponade, but in obstructive airway disease associated with pulsus paradoxus.

Entities:  

Mesh:

Year:  1977        PMID: 923064     DOI: 10.1161/01.cir.56.6.951

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  7 in total

1.  Pulsus paradoxus.

Authors:  A C Dornhorst
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

2.  Tamponade. Weekly case discussion.

Authors:  P Peeters; J L Vincent; J Unger
Journal:  Intensive Care Med       Date:  1986       Impact factor: 17.440

3.  The paradox of the paradoxical pulse.

Authors:  N O Fowler; P J Engel; H P Settle; R Shabetai
Journal:  Trans Am Clin Climatol Assoc       Date:  1979

4.  Sequential study of echocardiographic changes in purulent pericarditis.

Authors:  G Björkhem; N R Lundström; A Vitarelli
Journal:  Pediatr Cardiol       Date:  1984       Impact factor: 1.655

5.  Left ventricular function in presence of small pericardial effusion. Echocardiography study.

Authors:  G Firestein; C Hensley; P J Varghese
Journal:  Br Heart J       Date:  1980-04

6.  Dynamic effects of pericardial effusion without tamponade. Respiratory responses in the absence of pulsus paradoxus.

Authors:  V S Wayne; R L Bishop; D H Spodick
Journal:  Br Heart J       Date:  1984-02

7.  Mechanism study of pulsus paradoxus using mechanical models.

Authors:  Chang-yang Xing; Tie-sheng Cao; Li-jun Yuan; Zhen Wang; Kun Wang; Hua-ri Ren; Yong Yang; Yun-you Duan
Journal:  PLoS One       Date:  2013-02-28       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.