T-loop position and anchorage control.

A J Kuhlberg1, C J Burstone.   

Abstract

The effect of off-center positioning on the force system produced by segmented 0.017 x 0.025-inch TMA T-loops was measured. A T-loop was designed to produce equal and opposite moments in the centered position. The spring was tested in seven positions, centered, 1, 2, and 3 mm toward the anterior attachment, and 1, 2, and 3 mm toward the posterior attachments. The horizontal force, vertical force, and alpha and beta moments were measured over 6 mm of spring activation. The results showed that the alpha/beta moment ratio was dependent only on the spring position, and independent of spring activation. Eccentric positioning of T-loop springs effectively produces a consistent moment differential through the range of spring activation.

Mesh:

Year:  1997        PMID: 9228836     DOI: 10.1016/s0889-5406(97)70268-3

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Understanding the basis of space closure in Orthodontics for a more efficient orthodontic treatment.

Authors:  Gerson Luiz Ulema Ribeiro; Helder B Jacob
Journal:  Dental Press J Orthod       Date:  2016 Mar-Apr

2.  Differences in the force system delivered by different beta-titanium wires in elaborate designs.

Authors:  Renato Parsekian Martins; Sergei Godeiro Fernandes Rabelo Caldas; Alexandre Antonio Ribeiro; Luís Geraldo Vaz; Roberto Hideo Shimizu; Lídia Parsekian Martins
Journal:  Dental Press J Orthod       Date:  2015 Nov-Dec

3.  Absolute anchorage with universal T-loop mechanics for severe deepbite and maxillary anterior protrusion and its 10-year stability.

Authors:  Yoon Jeong Choi; Chooryung Judi Chung; Kwangchul Choy; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

4.  Quantification of three-dimensional orthodontic force systems of T-loop archwires.

Authors:  Jie Chen; Serkis C Isikbay; Edward J Brizendine
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

5.  En masse retraction versus two-step retraction of anterior teeth in extraction treatment of bimaxillary protrusion.

Authors:  Nayef H Felemban; Fahad F Al-Sulaimani; Zuhair A Murshid; Ali H Hassan
Journal:  J Orthod Sci       Date:  2013-01

6.  Orthodontic Replacement of Lost Permanent Molar with Neighbor Molar: A Six-Year Follow-Up.

Authors:  Taisa Boamorte Raveli; Ricardo Lima Shintcovsk; Luegya Amorim Henriques Knop; Luana Paz Sampaio; Dirceu Barnabé Raveli
Journal:  Case Rep Dent       Date:  2017-11-29

7.  The T-loop in details.

Authors:  Amanda Frizzo Viecilli; Maria Perpétua Mota Freitas
Journal:  Dental Press J Orthod       Date:  2018-01

8.  Comparative assessment of the efficacy of closed helical loop and T-loop for space closure in lingual orthodontics-a finite element study.

Authors:  Ajay Chacko; Tripti Tikku; Rohit Khanna; Rana Pratap Maurya; Kamna Srivastava
Journal:  Prog Orthod       Date:  2018-05-28       Impact factor: 2.750

9.  Effect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loops.

Authors:  Saúl Matos de Castro; Rui Moreira; Ana Cristina Braga; Afonso Pinhão Ferreira; Maria Cristina Pollmann
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

Review 10.  Efficacy of orthodontic mini implants for en masse retraction in the maxilla: a systematic review and meta-analysis.

Authors:  Kathrin Becker; Annika Pliska; Caroline Busch; Benedict Wilmes; Michael Wolf; Dieter Drescher
Journal:  Int J Implant Dent       Date:  2018-10-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.