Abstract
Visual and electronic techniques for counting bovine platelets were investigated. The reference method used was hemacytometer counting of platelets in whole blood diluted with 0.85% NaCl solution. A whole blood platelet-rich plasma technique was imprecise and inaccurate. Isopycnic centrifugation of blood diluted in 8.01% NaCl solution (same density as platelets) was a precise technique, but the whole blood platelet count was underestimated. The most precise and accurate technique investigated was unit gravity sedimentation of a 1:100 dilution of blood with 10 ml of Isoton followed by electronic counting of platelets in the supernatant. This technique correlated very well with visual counting of bovine platelets (N = 77, y = 55 + 0.80x, r = 0.89, P less than 0.01).Entities:
Mesh:
Year: 1977 PMID: 922558 PMCID: PMC1277741
Source DB: PubMed Journal: Can J Comp Med ISSN: 0008-4050