Abstract

OBJECTIVE: The overall aim of this pilot study was to establish the usefulness and comparability of selected verbal and non-verbal methods in the quantification of sensory and affective aspects of dental pain associated with dentine hypersensitivity (DH).
DESIGN: The assessment of dental pain was conducted during an eight week clinical study. Patients were asked to rate their perception of dental pain using selected methods of quantification following tactile (Yeaple Probe-an electronic pressure-sensitive probe) and evaporative (cold air from a dental air syringe) stimulation; together with an overall assessment of perception to daily stimuli (e.g., cold air/water, toothbrushing, sweet and sour foods). The assessment methods used to quantify pain arising from DH were a continuous visual analogue scale (VAS), a 0-10 numerical rating VAS scale (NRS), and a separate intensity verbal descriptor (IVD) and unpleasantness verbal descriptor (UVD) word scales.
SETTING: A specialist department at a postgraduate dental institute and hospital in London, UK.
SUBJECTS: Twenty-five adult patients (8M + 17F) with a mean age of 42.6 years (95 per cent C.I. 38.8 to 46.4 years) attending the department for a clinical study evaluating the efficacy of a desensitising toothpaste agreed to participate. OUTCOME MEASURES: The study compared a continuous visual analogue scale (VAS), a 0-10 numerical rating visual analogue scale (NRS), and a separate intensity (IVD) and unpleasantness verbal descriptor (UVD) scales to quantify sensory and affective aspects of pain. An unweighted moving average technique was used to construct graphs of the relative frequency of reported severity gradings over a range of 0-10.
RESULTS: The results of the study indicated that cold air appeared to cause greater discomfort to the patient than tactile sensitivity, with the air intensity curve for both IVD and 0-10 VAS peaking at a severity score of 5 while continuous VAS peaked at a score of 3-4. All methods peaked at score 2 for tactile sensitivity. The UVD scale peaked at score 2-3 and again at 6 for air sensitivity, but conformed to the other scales by peaking at score 2 for tactile sensitivity. NRS and IVD scales therefore appeared to provide acceptable alternatives to continuous VAS, but the UVD scale, probably because of the imprecise nature of the words used in the scale, did not.
CONCLUSIONS: This study partially confirms previous conclusions that both verbal and non-verbal techniques quantify sensory and affective aspects of pain. However, the imprecise nature of UVD words provided misleading information in terms of both accuracy and sensitivity (except at very low levels of discomfort), when assessing pain arising from dentine hypersensitivity. In view of the highly subjective data arising from studies of this nature, the use of a moving average technique may be considered a more pragmatic method of analysis.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9225538

Source DB:  PubMed          Journal:  Community Dent Health        ISSN: 0265-539X            Impact factor:   1.349


  4 in total

1.  A double blind controlled trial comparing three treatment modalities for dentin hypersensitivity.

Authors:  Nilam Brahmbhatt; Neeta Bhavsar; Vishal Sahayata; Aneesha Acharya; Payal Kshatriya
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-05-01

Review 2.  How valid and applicable are current diagnostic criteria and assessment methods for dentin hypersensitivity? An overview.

Authors:  Christian R Gernhardt
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

3.  A randomized clinical trial of dentin hypersensitivity reduction over one month after a single topical application of comparable materials.

Authors:  Samar Hatem Abuzinadah; Abdulrahman Jafar Alhaddad
Journal:  Sci Rep       Date:  2021-03-24       Impact factor: 4.379

4.  A comparative evaluation to assess the efficacy of 5% sodium fluoride varnish and diode laser and their combined application in the treatment of dentin hypersensitivity.

Authors:  Isha Suri; Poonam Singh; Quaid Johar Shakir; Arvind Shetty; Ranjeet Bapat; Roshani Thakur
Journal:  J Indian Soc Periodontol       Date:  2016 May-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.