Heat transfer evaluation of the nasal thermistor technique.

K Storck1, M Karlsson, P Ask, D Loyd.   

Abstract

When analyzing transvalvular and venous flow velocity patterns, it is important to relate them to respiration. An accurate recording of respiratory phase can be carried out with different methods. One of these methods is the use of a thermistor, which reacts to the variation in air temperature, placed in the noise of the patient. The thermistor used has a diameter for 1.0 mm and is of standard bead type. Although small, it has a considerable long time-constant and a long time-delay. The high time-constant gives a low cutoff frequency, well below the respiratory frequency and thereby causing a large phase difference. The thermistor was analyzed with the lumped heat capacity method, where it was easy to study the influence from design parameters, time-dependent air temperature, and velocity. The analysis was extended using the finite element method and the temperature field in the thermistor and the probe was calculated as a function of space and time. These calculations confirmed the result from the lumped model. The result showed that timing of respiration was not accurately obtained with the thermistor analyzed. To improve the timing, it was necessary either to change the measuring method or to use signal processing in order to achieve faster response.

Entities:  

Mesh:

Year:  1996        PMID: 9214837     DOI: 10.1109/10.544342

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units.

Authors:  Ambra Cesareo; Emilia Biffi; David Cuesta-Frau; Maria G D'Angelo; Andrea Aliverti
Journal:  Med Biol Eng Comput       Date:  2020-01-30       Impact factor: 2.602

Review 2.  Implementation of Thermal Camera for Non-Contact Physiological Measurement: A Systematic Review.

Authors:  Martin Clinton Tosima Manullang; Yuan-Hsiang Lin; Sheng-Jie Lai; Nai-Kuan Chou
Journal:  Sensors (Basel)       Date:  2021-11-23       Impact factor: 3.576

3.  NaCl Ionization-Based Moisture Sensor Prepared by Aerosol Deposition for Monitoring Respiratory Patterns.

Authors:  Myung-Yeon Cho; Ik-Soo Kim; Min-Ji Kim; Da-Eun Hyun; Sang-Mo Koo; Hiesang Sohn; Nam-Young Kim; Sunghoon Kim; Seunghoon Ko; Jong-Min Oh
Journal:  Sensors (Basel)       Date:  2022-07-11       Impact factor: 3.847

4.  Techniques for clutter suppression in the presence of body movements during the detection of respiratory activity through UWB radars.

Authors:  Antonio Lazaro; David Girbau; Ramon Villarino
Journal:  Sensors (Basel)       Date:  2014-02-07       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.