Literature DB >> 9212947

Cora rotary pump for implantable left ventricular assist device: biomaterial aspects.

J R Montiès1, I Dion, P Havlik, F Rouais, J Trinkl, C Baquey.   

Abstract

Our group is developing a left ventricular assist device based on the principle of the Maillard-Wankel rotative compressor: it is a rotary, not centrifugal, pump that produces a pulsatile flow. Stringent requirements have been defined for construction materials. They must be light, yet sufficiently hard and rigid, and able to be machined with high precision. The friction coefficient must be low and the wear resistance high. The materials must be chemically inert and not deformable. Also, the materials must be biocompatible, and the blood contacting surface must be hemocompatible. We assessed the materials in terms of physiochemistry, mechanics, and tribology to select the best for hemocompatibility (determined by studies of protein adsorption; platelet, leukocyte, and red cell retention; and hemolysis, among other measurements) and biocompatibility (determined by measurement of complement activation and toxicity, among other criteria). Of the materials tested, for short- and middle-term assistance, we chose titanium alloy (Ti6Al4V) and alumina ceramic (Al2O3) and for long-term and permanent use, composite materials (TiN coating on graphite). We saw that the polishing process of the substrate must be improved. For the future, the best coating material would be diamond-like carbon (DLC) or crystalline diamond coating.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9212947     DOI: 10.1111/j.1525-1594.1997.tb03731.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  5 in total

1.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

Review 2.  Nanoporous membranes for medical and biological applications.

Authors:  Shashishekar P Adiga; Chunmin Jin; Larry A Curtiss; Nancy A Monteiro-Riviere; Roger J Narayan
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2009 Sep-Oct

3.  Hemolysis caused by surface roughness under shear flow.

Authors:  Osamu Maruyama; Yusuke Numata; Masahiro Nishida; Takashi Yamane; Ikuya Oshima; Yoshikazu Adachi; Toru Masuzawa
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.385

4.  Design and Experimental Study of a Tetragonal Rotor Pump Based on Wankel Geometry.

Authors:  Zhenzhen Gui; Xiaosi Zhou; Yaohua Zeng; Fan Zhang; Yuxuan Huo; Weirong Zhang; Mingdong Ma; Xi Huang; Jianhui Zhang
Journal:  Sensors (Basel)       Date:  2022-09-01       Impact factor: 3.847

Review 5.  Control of Blood Coagulation by Hemocompatible Material Surfaces-A Review.

Authors:  Janna Kuchinka; Christian Willems; Dmitry V Telyshev; Thomas Groth
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.