Literature DB >> 9212387

Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study.

C Y Yang1, B C Wang, T M Lee, E Chang, G L Chang.   

Abstract

An intramedullary implant model in the canine femora was developed to evaluate the mechanical and histological responses between cancellous bone and plasma-sprayed hydroxyapatite coatings (HACs) on ti-6A1-4V implants, with 12- and 24-week follow-ups. HACs of different thicknesses were investigated. Results of the mechanical testings revealed that after 24 weeks of implantation, the mean shear strength (2.49 +/- 0.12 MPa) of the 50 microns HACs was significantly higher (p < 0.05) than that of the 200 microns HACs (1.44 +/- 0.19 MPa). However, using backscattered electron images (BEIs) throughout all the implant periods, no substantial histological variations in the extent of new bone apposition between the two HACs were observed. Occasionally, solution-mediated disintegration of the 50 microns HAC was found 24 weeks postimplantation. Histomorphometric studies from the BEIs demonstrated that for both HACs the percentage of the direct HAC-cancellous bone contact was approximately 50% at 12 weeks and 75% at 24 weeks. After the mechanical tests, the 200 microns HACs had fracture sites either inside the coating layers or at the HAC-titanium interfaces, which might explain why the mechanical performance of the 200 microns HACs was inferior to that of the 50 microns HACs even though both HACs had the same histological behaviors.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9212387     DOI: 10.1002/(sici)1097-4636(199707)36:1<39::aid-jbm5>3.0.co;2-m

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

Review 1.  Calcium Phosphate Bioceramics: A Review of Their History, Structure, Properties, Coating Technologies and Biomedical Applications.

Authors:  Noam Eliaz; Noah Metoki
Journal:  Materials (Basel)       Date:  2017-03-24       Impact factor: 3.623

2.  Biological responses of neonatal rat calvarial osteoblasts on plasma-sprayed HA/ZrO2 composite coating.

Authors:  T M Lee; R S Tsai; E Chang; C Y Yang; M R Yang
Journal:  J Mater Sci Mater Med       Date:  2002-03       Impact factor: 3.896

3.  Calcium orthophosphate coatings, films and layers.

Authors:  Sergey V Dorozhkin
Journal:  Prog Biomater       Date:  2012-09-26

4.  Three-Dimensional Printed Porous Titanium Screw with Bioactive Surface Modification for Bone-Tendon Healing: A Rabbit Animal Model.

Authors:  Yu-Min Huang; Chih-Chieh Huang; Pei-I Tsai; Kuo-Yi Yang; Shin-I Huang; Hsin-Hsin Shen; Hong-Jen Lai; Shu-Wei Huang; San-Yuan Chen; Feng-Huei Lin; Chih-Yu Chen
Journal:  Int J Mol Sci       Date:  2020-05-21       Impact factor: 5.923

  4 in total