Literature DB >> 9209934

Guide wire outer coat shearing and embolisation: an unusual complication of pericardiocentesis.

S C Reddy1, P Kamath, K K Talwar, A Saxena, H S Wasir.   

Abstract

We report a case of shearing of the outer coat of the guide wire and its embolization into the pulmonary artery during pericardiocentesis. This unusual foreign body was successfully removed by pervenous method.

Mesh:

Year:  1997        PMID: 9209934     DOI: 10.1016/s0167-5273(97)02965-3

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  2 in total

1.  Successful removal of kinked J-guide wire under fluoroscopic guidance during central venous catheterization -A case report-.

Authors:  Hyun-Seok Han; Young-Tae Jeon; Hyo-Seok Na; Jin-Young Hwang; Eun-Joo Choi; Mi-Hyun Kim
Journal:  Korean J Anesthesiol       Date:  2011-05-31

2.  Complications of pericardiocentesis: A clinical synopsis.

Authors:  Rajan Kumar; Archana Sinha; Maggie J Lin; Reina Uchino; Tracy Butryn; M Shay O'Mara; Sudip Nanda; Jamshid Shirani; Stanislaw P Stawicki
Journal:  Int J Crit Illn Inj Sci       Date:  2015 Jul-Sep
  2 in total