Literature DB >> 9207516

Percutaneous nephrostomy: placement under CT and fluoroscopy guidance.

Z L Barbaric1, T Hall, S T Cochran, D R Heitz, R A Schwartz, R M Krasny, M W Deseran.   

Abstract

OBJECTIVE: The purpose of this paper is to present our experience with CT- and fluoroscopy-guided percutaneous nephrostomy tube (PNT) placement and to describe the technique of placement with patients in the supine-oblique position.
MATERIALS AND METHODS: A CT scanner was coupled with a ceiling-mounted C-arm for fluoroscopy at the CT table, PNT was done with CT localization and fluoroscopic control. We attempted 148 placements in 129 patients, with most patients in the supine or the supine-oblique position.
RESULTS: Successful PNT placement was achieved in 144 (97%) of 148 kidneys. In the native kidney group, 101 (81%) of 124 PNTs were placed with the patients in the supine-oblique position. We experienced no major complications, three (2%) minor complications, and two (1%) catheter dislodgments.
CONCLUSION: CT-fluoroscopy control allows routine PNT placement with patients in the supine or the supine-oblique position and is associated with the lowest complication rate to our knowledge.

Entities:  

Mesh:

Year:  1997        PMID: 9207516     DOI: 10.2214/ajr.169.1.9207516

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Percutaneous nephrostomy: placement under laser guidance and real-time CT fluoroscopy.

Authors:  L LeMaitre; P Mestdagh; J Marecaux-Delomez; P Valtille; F Dubrulle; J Biserte
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

Review 2.  Percutaneous nephrostomy and antegrade ureteral stenting: technique-indications-complications.

Authors:  Klaus Armin Hausegger; Horst Rupert Portugaller
Journal:  Eur Radiol       Date:  2006-03-18       Impact factor: 5.315

3.  MRI-guided percutaneous nephrostomy: a feasibility study.

Authors:  Juho Kariniemi; Roberto Blanco Sequeiros; Risto Ojala; Osmo Tervonen
Journal:  Eur Radiol       Date:  2008-11-26       Impact factor: 5.315

4.  [Placement of percutaneous nephrostomy by open magnetic resonance imaging: clinical results and current status in urology].

Authors:  M Porsch; J J Wendler; F Fischbach; D Schindele; A Janitzky; D Baumunk; U-B Liehr; J Ricke; M Schostak
Journal:  Urologe A       Date:  2012-12       Impact factor: 0.639

5.  Emergency percutaneous nephrostomy.

Authors:  Sidney P Regalado
Journal:  Semin Intervent Radiol       Date:  2006-09       Impact factor: 1.513

6.  Kidney access device.

Authors:  Jasneet Singh Bhullar; Robert Scott; Mitesh Patel; Vijay K Mittal
Journal:  JSLS       Date:  2014 Oct-Dec       Impact factor: 2.172

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.