Literature DB >> 920306

[Intracranial volume fluctuations. The importance of exact CSF-measurements in CSF-drainages (author's transl)].

E C Fuchs.   

Abstract

The significance of simultaneous I.C.P. measurements together with exact C.S.F. volume measurements through the same ventricular catheter is emphasized. A new method using an electronic device is introduced. Volume fluctuations are shown as correlations of plateau waves. The fluctuating amount of C.S.F. (the probable equivalent of a plateau wave) ranges between 16 and 32 ml. Only with disturbed autoregulation is there a close correlation between the S.A.P. and the I.C.V. (intracranial volume) change. Simultaneous I.C.P. measurements up to a maximum pressure, determined by the level of the drainage system and corresponding to the primary brain dysfunction, together with electronic measurement of the drained C.S.F., seem to be ideal for the patient and for scientific purposes.

Entities:  

Mesh:

Year:  1977        PMID: 920306     DOI: 10.1007/bf01401093

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  7 in total

1.  [On "cerebrospinal fluid crises" - spontaneous pressure fluctuation in intracranial spinal fluid passage disorders].

Authors:  W GROTE; R WUELLENWEBER
Journal:  Acta Neurochir (Wien)       Date:  1960       Impact factor: 2.216

2.  Continuous recording and control of ventricular fluid pressure in neurosurgical practice.

Authors:  N LUNDBERG
Journal:  Acta Psychiatr Scand Suppl       Date:  1960

3.  A simplified apparatus for constant ventricular drainage.

Authors:  E A BERING
Journal:  J Neurosurg       Date:  1951-07       Impact factor: 5.115

4.  Acute spontaneous volume fluctuation in the brain. A contribution to the interpretation of plateau waves. Results of CSF measurements with ventricular drainage.

Authors:  E C Fuchs
Journal:  Neurochirurgia (Stuttg)       Date:  1976-07

5.  Disposable system for intraventricular pressure measurement and CSF drainage. Technical note.

Authors:  H M Shapiro; S R Wyte; A B Harris; A Galindo
Journal:  J Neurosurg       Date:  1972-06       Impact factor: 5.115

6.  Temporary control of cerebrospinal fluid volume and pressure by means of an externalized valve-drainage system.

Authors:  R J White; J G Dakters; D Yashon; M S Albin
Journal:  J Neurosurg       Date:  1969-03       Impact factor: 5.115

7.  Regional cerebral blood volume during acute transient rises of the intracranial pressure (plateau waves).

Authors:  J Risberg; N Lundberg; D H Ingvar
Journal:  J Neurosurg       Date:  1969-09       Impact factor: 5.115