Literature DB >> 9202354

Low-energy endocardial defibrillation using dual, triple, and quadruple electrode systems.

A N Munsif1, S Saksena, P DeGroot, R B Krol, P Matthew, I Giorgberidze, R R Kaushik, R Mehra.   

Abstract

The feasibility of achieving both universal application of nonthoracotomy leads and low (< or = 15 J) defibrillation energy requirements by optimizing lead system configuration for use with low-output (<30 J) biphasic shock pulse generators was examined. Sixteen patients (mean age 62 +/- 8 years and mean left ventricular ejection fraction of 38 +/- 15%) were included in the study. All patients had either experienced syncope with induced ventricular tachycardia (n = 4) or had documented sustained ventricular tachycardia (n = 7) or ventricular fibrillation (n = 5). Defibrillation threshold testing was performed in 2 stages on different days in these patients. In the first stage, 2 defibrillation catheter electrodes were positioned in the right ventricle and superior vena cava with an axillary cutaneous patch. Fifteen-joule, 10- and 5-J biphasic shocks were delivered across 3 different electrode configurations-right ventricle to superior vena cava, right ventricle to axillary patch, right ventricle to a combination of superior vena cava and axillary patch. In the second stage, an 80-ml can electrode was added subcutaneously in a pectoral location to the previous leads. Configurations compared were the right ventricle to pectoral can, and right ventricle to an "array"-combining superior vena cava, can, and axillary patch leads. The defibrillation threshold was determined using a step-down method. In stage 1, mean defibrillation threshold for the right ventricle to axillary patch (12.7 +/- 5.9 J) and right ventricle to superior vena cava plus axillary patch (9.8 +/- 5.2 J) configurations was lower than the right ventricle to superior vena cava configuration (14.2 +/- 6.4 J, p <0.05). In stage 2, the defibrillation was higher for the right ventricle to pectoral can (9.2 +/- 5.1 J) configuration compared with the right ventricle to the array (5.6 +/- 3.6 J, p < or =0.05). The right ventricle to array had the lowest defibrillation threshold, whereas the right ventricle to pectoral can was the best dual electrode system. Low-energy endocardial defibrillation (< or =10 J) was feasible in 72% of tested patients with > 1 electrode configuration at 10 J, whereas only 53% of successful patients could be reverted at >1 electrode configuration at 5 J (p <0.05). Reduction in maximum pulse generator output to < or =25 J using these electrode configurations with bidirectional shocks is feasible and maintains an adequate safety margin.

Entities:  

Mesh:

Year:  1997        PMID: 9202354     DOI: 10.1016/s0002-9149(97)00212-9

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

1.  The leadless defibrillator or the return of the subcutaneous electrode: episode III in the ICD saga?

Authors:  Sanjeev Saksena
Journal:  J Interv Card Electrophysiol       Date:  2005-09       Impact factor: 1.900

Review 2.  Non-traditional implantable cardioverter-defibrillator configurations and insertion techniques: a review of contemporary options.

Authors:  Johanna B Tonko; Christopher A Rinaldi
Journal:  Europace       Date:  2022-02-02       Impact factor: 5.214

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.