Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model.

G A Breit1, J H Gross, D E Watenpaugh, B Chance, A R Hargens.   

Abstract

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

Entities:  

Keywords:  NASA Center ARC; NASA Discipline Cardiopulmonary; NASA Discipline Musculoskeletal

Mesh:

Substances:

Year:  1997        PMID: 9199380     DOI: 10.2106/00004623-199706000-00006

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  9 in total

1.  Application of spectral derivative data in visible and near-infrared spectroscopy.

Authors:  Hamid Dehghani; Frederic Leblond; Brian W Pogue; Fabien Chauchard
Journal:  Phys Med Biol       Date:  2010-05-26       Impact factor: 3.609

Review 2.  Numerical modelling and image reconstruction in diffuse optical tomography.

Authors:  Hamid Dehghani; Subhadra Srinivasan; Brian W Pogue; Adam Gibson
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2009-08-13       Impact factor: 4.226

3.  Spectral filtering modulation method for estimation of hemoglobin concentration and oxygenation based on a single fluorescence emission spectrum in tissue phantoms.

Authors:  Quan Liu; Tuan Vo-Dinh
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

4.  Stiffness and thickness of fascia do not explain chronic exertional compartment syndrome.

Authors:  Morten Dahl; Philip Hansen; Per Stål; David Edmundsson; S Peter Magnusson
Journal:  Clin Orthop Relat Res       Date:  2011-09-24       Impact factor: 4.176

5.  Reliability of near-infrared spectroscopy in people with dark skin pigmentation.

Authors:  E B Wassenaar; J G H Van den Brand
Journal:  J Clin Monit Comput       Date:  2005-06       Impact factor: 2.502

6.  Hemodynamic changes in rat leg muscles during tourniquet-induced ischemia-reperfusion injury observed by near-infrared spectroscopy.

Authors:  J G Kim; J Lee; J Roe; B J Tromberg; M Brenner; T J Walters
Journal:  Physiol Meas       Date:  2009-05-13       Impact factor: 2.833

7.  Noninvasive monitoring of elevated intramuscular pressure in a model compartment syndrome via quantitative fascial motion.

Authors:  John E Lynch; John K Lynch; Steven L Cole; Jonathan A Carter; Alan R Hargens
Journal:  J Orthop Res       Date:  2009-04       Impact factor: 3.494

8.  Investigation of spectral interferences on the accuracy of broadband CW-NIRS tissue SO(2) determination.

Authors:  Fengmei Zou; Chunguang Jin; Randy R Ross; Babs Soller
Journal:  Biomed Opt Express       Date:  2010-08-30       Impact factor: 3.732

9.  Male sex, height, weight, and body mass index can increase external pressure to calf region using knee-crutch-type leg holder system in lithotomy position.

Authors:  Ju Mizuno; Toru Takahashi
Journal:  Ther Clin Risk Manag       Date:  2016-02-25       Impact factor: 2.423

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.