Literature DB >> 9197098

Functional loads on freestanding and connected implants in three-unit mandibular prostheses opposing complete dentures: an in vivo study.

J Gunne1, B Rangert, P O Glantz, A Svensson.   

Abstract

In vivo measurements of vertical forces and bending moments during biting and chewing were carried out on 10 three-unit prostheses in the posterior mandibles of five patients. Each patient had two prostheses, one supported by two implants and the other supported by one implant and one tooth. The results demonstrated no major difference in functional load magnitudes related to the support type. The distribution of load between the abutments was influenced more by the prosthesis geometry and implant placement than by the difference in load characteristics of tooth and implant. This conclusion, however, is limited to one implant connected to a tooth, because multiple implants form a considerably stiffer unit than do teeth. An increase in vertical load resulting from cantilever extensions on the prostheses was documented, both at bite fork measurements and during chewing. No substantial lateral bending was registered, probably because the flat occlusal surfaces and the presence of the opposing complete denture reduced lateral forces.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9197098

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

2.  Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible.

Authors:  Yuta Shimura; Yuji Sato; Noboru Kitagawa; Miyuki Omori
Journal:  Int J Implant Dent       Date:  2016-06-17

Review 3.  Combined Implant and Tooth Support: An Up-to-Date Comprehensive Overview.

Authors:  Mahmoud K Al-Omiri; Maher Al-Masri; Mohannad M Alhijawi; Edward Lynch
Journal:  Int J Dent       Date:  2017-03-23

4.  Correlation between abutment angulation and off-axial stresses on biomechanical behavior of titanium and zirconium implants in the anterior maxilla: A three-dimensional finite element analysis study.

Authors:  Harilal Guguloth; Chalapathi Rao Duggineni; Ravi Kumar Chitturi; M Sujesh; T Ravvali; Roja Roshan Amiti
Journal:  J Indian Prosthodont Soc       Date:  2019-10-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.