Literature DB >> 9192942

A system to generate simultaneous forced oscillation and continuous positive airway pressure.

R Farré1, M Rotger, J M Montserrat, D Navajas.   

Abstract

Assessment of airway obstruction in patients with obstructive sleep apnoea (OSA) subjected to continuous positive airway pressure (CPAP) may be carried out using the forced oscillation technique (FOT). To facilitate routine application of forced oscillation (FO) in sleep studies, our aim was to design a system capable of generating CPAP and applying FOT simultaneously. We constructed a prototype CPAP + FO generator by connecting a specially designed electromagnetic valve in parallel with a conventional blower. The capacity of the prototype to generate forced oscillation (5 Hz +/- 1 hPa) was tested by connecting it to a model simulating spontaneous breathing. The response of the prototype for target CPAPs of 5, 10 and 15 hPa and imposed sinusoidal breathing with peak flow up to 0.75 L x s(-1) was excellent when compared with that reported for commercially available CPAP generators. The applicability of the prototype was tested by applying it to assess airway obstruction in four patients with OSA during sleep. We conclude that the generator designed is able to apply continuous positive airway pressure and forced oscillation simultaneously. The system could be useful for automatic and noninvasive assessment of airway obstruction in patients with obstructive sleep apnoea subjected to continuous positive airway pressure. Future development of the generator may be helpful in implementing a set-up for automatic titration of continuous positive airway pressure.

Entities:  

Mesh:

Year:  1997        PMID: 9192942     DOI: 10.1183/09031936.97.10061349

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  6 in total

1.  Improvement of CPAP Therapy by a Self-Adjusting System.

Authors:  Katrin Pilz; Stefan Thalhofer; Philipp Meissner; Peter Dorow
Journal:  Sleep Breath       Date:  2000       Impact factor: 2.816

Review 2.  Oscillation mechanics of the respiratory system: applications to lung disease.

Authors:  David W Kaczka; Raffaele L Dellacá
Journal:  Crit Rev Biomed Eng       Date:  2011

3.  Measuring upper and lower airway resistance during sleep with the forced oscillation technique.

Authors:  Lisa M Campana; R L Owens; B Suki; A Malhotra
Journal:  Ann Biomed Eng       Date:  2011-11-30       Impact factor: 3.934

4.  Does either obesity or OSA severity influence the response of autotitrating CPAP machines in very obese subjects?

Authors:  Chris D Turnbull; Ari R Manuel; John R Stradling
Journal:  Sleep Breath       Date:  2015-10-08       Impact factor: 2.816

5.  Forced oscillation assessment of respiratory mechanics in ventilated patients.

Authors:  D Navajas; R Farré
Journal:  Crit Care       Date:  2000-12-20       Impact factor: 9.097

6.  Relationships between MRI fat distributions and sleep apnea and obesity hypoventilation syndrome in very obese patients.

Authors:  C D Turnbull; S H Wang; A R Manuel; B T Keenan; A G McIntyre; R J Schwab; J R Stradling
Journal:  Sleep Breath       Date:  2017-12-02       Impact factor: 2.816

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.