The development of an isokinetic squat device: reliability and relationship to functional performance.

G J Wilson1, A D Walshe, M R Fisher.   

Abstract

This study was performed to determine the reliability and validity of a new isokinetic squat device in comparison to knee-extension tests performed using a Cybex. Athletic male subjects (n = 29) performed a series of isokinetic squat tests at 0.4 m.s-1, knee-extension tests at 1.05, 2.09 and 3.14 rad.s-1, and a 6-s stationary cycle test which was used as the measure of functional performance. The squat tests included a purely concentric squat without pre-load, a test with pre-load and a stretch-shorten cycle test. Two trials of each test were performed on one testing occasion. Intraclass correlation co-efficients (r = 0.89-0.96) and co-efficients of variation (3.1-8.7%) were determined between trials, and these indicated that all of the tests were highly reliable. The velocity characteristics of the newly developed system demonstrated that it was an effective isokinetic device, with the mean velocity of 0.41 m.s-1 varying within narrow limits, a relatively small velocity overshoot and an isokinetic portion of movement of approximately 80%. The squat tests demonstrated a higher relationship to cycling performance (r = 0.57-0.65) as compared to the knee-extension tests (r = 0.45-0.51). This difference was amplified when a more homogeneous group of subjects was examined. Further, the squat tests were superior to the knee-extension tests in discriminating between differing levels of cycling performance ability. These differences were believed to be due to the greater specificity of the squat movement, in comparison to the knee extension, to the performance of interest.

Mesh:

Year:  1997        PMID: 9189735     DOI: 10.1007/s004210050188

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  5 in total

1.  Reliability and validity of a wireless microelectromechanicals based system (keimove™) for measuring vertical jumping performance.

Authors:  Bernardo Requena; Inmaculada García; Francisco Requena; Eduardo Saez-Saez de Villarreal; Mati Pääsuke
Journal:  J Sports Sci Med       Date:  2012-03-01       Impact factor: 2.988

2.  A new device for controlled eccentric overloading in training and rehabilitation.

Authors:  Anna Frohm; Kjartan Halvorsen; Alf Thorstensson
Journal:  Eur J Appl Physiol       Date:  2005-02-18       Impact factor: 3.078

3.  The Effects of Multiple-Joint Isokinetic Resistance Training on Maximal Isokinetic and Dynamic Muscle Strength and Local Muscular Endurance.

Authors:  Nicholas A Ratamess; Noah A Beller; Adam M Gonzalez; Gregory E Spatz; Jay R Hoffman; Ryan E Ross; Avery D Faigenbaum; Jie Kang
Journal:  J Sports Sci Med       Date:  2016-02-23       Impact factor: 2.988

4.  Reliability and agreement of the IsoKai isokinetic lift test - A test used for admission to the Swedish Armed Forces.

Authors:  Tony Bohman; Matthias Tegern; Alexandra Halvarsson; Lisbet Broman; Helena Larsson
Journal:  PLoS One       Date:  2018-12-19       Impact factor: 3.240

5.  Development of Magnetorheological Resistive Exercise Device for Rowing Machine.

Authors:  Vytautas Grigas; Anatolijus Šulginas; Pranas Žiliukas
Journal:  Comput Math Methods Med       Date:  2016-05-18       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.