S T Wu1, Y P Chang, W L Gee, L Z Benet, E T Lin.
Abstract
A stereoselective reversed-phase HPLC assay to quantify S-(-) and R-(+) enantiomers of propranolol and 4-hydroxypropranolol in human plasma was developed. The method involved liquid-liquid extraction for sample clean-up and employed 2,3,4,6-tetra-O-acetyl-beta-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The internal standard used was 4-methylpropranolol. The derivatized products were separated on an Altex C18 column using a mixture of acetonitrile-water-phosphoric acid-triethylamine (58:42:0.1:0.06 and 50:50:0.15:0.06, v/v, for propranolol and 4-hydroxypropranolol, respectively) as mobile phase. The detection of propranolol derivatives was made at lambda(ex)=280 nm and lambda(em)=325 nm, and the corresponding 325 and 400 nm were used for 4-hydroxypropranolol derivatives. The assay was linear from 1 to 100 ng/ml and from 2 to 50 ng/ml using 0.5 ml of human plasma for propranolol and 4-hydroxypropranolol enantiomers, respectively. The present assay is used to quantify the enantiomers of propranolol and 4-hydroxypropranolol, respectively, in human plasma for pharmacokinetic studies.Entities:
Mesh:
Substances:
Year: 1997 PMID: 9187392 DOI: 10.1016/s0378-4347(96)00313-1
Source DB: PubMed Journal: J Chromatogr B Biomed Sci Appl ISSN: 1387-2273