Literature DB >> 9187389

High-performance liquid chromatography-ionspray mass spectrometry for the specific determination of digoxin and some related cardiac glycosides in human plasma.

A Tracqui1, P Kintz, B Ludes, P Mangin.   

Abstract

An original method based upon high-performance liquid chromatography coupled to ionspray mass spectrometry (HPLC-ISP-MS) has been developed for the identification and quantification in plasma of several cardiac glycosides, namely digoxin, digitoxin, lanatoside C and acetyldigitoxin. After single-step liquid-liquid extraction by chloroform-2-propanol (95:5, v/v) at pH 9.5 using oleandrin as an internal standard, solutes are separated on a 4 microm NovaPak C18 (Waters) column (150x2.0 mm, I.D.), using a gradient of acetonitrile-2 mM NH4COOH, pH 3 buffer (flow-rate 200 microl/min, post-column split 1:3). Detection is done by a Perkin-Elmer Sciex API-100 mass analyzer equipped with an ISP interface. In most instances the major ion observed is not [M+H]+ as expected, but [M+NH4]+. The mean retention times (min) are: lanatoside C, 5.74; digoxin, 6.00; digitoxin, 8.08, oleandrin, 8.30, acetyldigitoxin, 8.66 and 9.01 (isomers alpha and beta, respectively). The lower limits of detection in single ion monitoring mode range from 0.15 ng/ml (alpha- and beta-acetyldigitoxin) to 0.60 ng/ml (lanatoside C), making the method less sensitive than radioimmunoassay, whereas it is much more specific.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9187389     DOI: 10.1016/s0378-4347(96)00462-8

Source DB:  PubMed          Journal:  J Chromatogr B Biomed Sci Appl        ISSN: 1387-2273


  4 in total

1.  A non-fatal oleander poisoning.

Authors:  J Pietsch; R Oertel; S Trautmann; K Schulz; B Kopp; J Dressler
Journal:  Int J Legal Med       Date:  2005-05-20       Impact factor: 2.686

2.  LC-MS assay for quantitative determination of cardio glycoside in human blood samples.

Authors:  L Frommherz; H Köhler; B Brinkmann; M Lehr; J Beike
Journal:  Int J Legal Med       Date:  2007-06-14       Impact factor: 2.686

3.  Analysis of digoxin and metildigoxin in whole blood using solid-phase extraction and liquid chromatography tandem mass spectrometry.

Authors:  Paula Melo; Rita Machado; Helena M Teixeira
Journal:  Int J Anal Chem       Date:  2011-06-22       Impact factor: 1.885

4.  Development of a new ultra-high-performance liquid chromatography-tandem mass spectrometry method for the determination of digoxin and digitoxin in plasma: Comparison with a clinical immunoassay.

Authors:  Marco Ballotari; Francesco Taus; Giulia Tolle; Elisa Danese; Romolo M Dorizzi; Franco Tagliaro; Rossella Gottardo
Journal:  Electrophoresis       Date:  2022-02-17       Impact factor: 3.595

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.