Literature DB >> 9187176

Electromyographic response to exercise in cardiac transplant patients: a new method for anaerobic threshold determination?

A Lucía1, A F Vaquero, M Pérez, O Sánchez, V Sánchez, M A Gómez, J L Chicharro.   

Abstract

The purpose of this study was to investigate the possible use of integrated surface electromyography (iEMG) in cardiac transplant patients (CTPs) as a new noninvasive determinant of the metabolic response to exercise by studying the relationship between the iEMG threshold (iEMGT) and other more conventional methods for anaerobic threshold (AT) determination, such as the lactate threshold (LT) and the ventilatory threshold (VT). Thirteen patients (age: 57+/-7 years, mean+/-SD; height: 163+/-7 cm; body mass: 70.5+/-8.6 kg; posttransplant time: 87+/-49 weeks) were selected as subjects. Each of them performed a ramp protocol on a cycle ergometer (starting at 0 W, the workload was increased in 10 W/min). During the tests, gas exchange data, blood lactate levels, and iEMG of the vastus lateralis were collected to determine VT, LT, and iEMGT, respectively. The results evidenced no significant difference between mean values of VT, LT, or iEMGT, when expressed either as oxygen uptake (11.1+/-2.4, 11.7+/-2.3, and 11.0+/-2.8 mL/kg/min, respectively) or as percent maximum oxygen uptake (61.6+/-7.5, 62.2+/-7.7, and 59.6+/-8.2%, respectively). In conclusion, our findings suggest that iEMG might be used as a complementary, noninvasive method for AT determination in CTPs. In addition, since the aerobic impairment of these patients is largely due to peripheral limitation, determination of iEMGT could be used to assess the effectiveness of an exercise rehabilitation program to improve muscle aerobic capacity in CTPs.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9187176     DOI: 10.1378/chest.111.6.1571

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  5 in total

1.  Analysis of the aerobic-anaerobic transition in elite cyclists during incremental exercise with the use of electromyography.

Authors:  A Lucía; O Sánchez; A Carvajal; J L Chicharro
Journal:  Br J Sports Med       Date:  1999-06       Impact factor: 13.800

2.  Assessment of Subjective Perceived Exertion at the Anaerobic Threshold with the Borg CR-10 Scale.

Authors:  Antonio R Zamunér; Marlene A Moreno; Taís M Camargo; Juliana P Graetz; Ana C S Rebelo; Nayara Y Tamburús; Ester da Silva
Journal:  J Sports Sci Med       Date:  2011-03-01       Impact factor: 2.988

3.  Surface Electromyography Thresholds as a Measure for Performance Fatigability During Incremental Cycling in Patients With Neuromuscular Disorders.

Authors:  Nicoline B M Voet; Christiaan G J Saris; Dick H J Thijssen; Vincent Bastiaans; David E Sluijs; Mariska M H P Janssen
Journal:  Front Physiol       Date:  2022-03-17       Impact factor: 4.566

4.  Identification and agreement of first turn point by mathematical analysis applied to heart rate, carbon dioxide output and electromyography.

Authors:  Antonio R Zamunér; Aparecida M Catai; Luiz E B Martins; Daniel I Sakabe; Ester Da Silva
Journal:  Braz J Phys Ther       Date:  2013-11-14       Impact factor: 3.377

5.  Detection of ventilatory thresholds using near-infrared spectroscopy with a polynomial regression model.

Authors:  Chih-Wei Lin; Chun-Feng Huang; Jong-Shyan Wang; Li-Lan Fu; Tso-Yen Mao
Journal:  Saudi J Biol Sci       Date:  2020-03-12       Impact factor: 4.219

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.