Literature DB >> 9185486

A 3 year audit of fine needle aspirates from a symptomatic breast clinic.

T F Lioe1, H Elliott, D C Allen, R A Spence.   

Abstract

A total of 2431 fine needle aspirates of symptomatic breast lumps was performed on 2096 patients over the last three years at the weekly head, neck and breast clinic at the Belfast City Hospital Trust. Diagnostic accuracy was achieved within the recommended standards although the "insufficient" rate was high at 31.8%. False negative and positive rates were low and the positive predictive value for malignancy was 99%. Excision biopsy for benign breast disease had decreased by almost a third during this period. Fine needle aspiration cytology is a highly accurate and cost-effective technique for the investigation of symptomatic breast lumps and results in significant savings.

Entities:  

Mesh:

Year:  1997        PMID: 9185486      PMCID: PMC2448706     

Source DB:  PubMed          Journal:  Ulster Med J        ISSN: 0041-6193


  6 in total

1.  Evidence that the sensitivity is increased and the inadequacy rate decreased when pathologists take aspirates for cytodiagnosis.

Authors:  A F Padel; S B Coghill; S J Powis
Journal:  Cytopathology       Date:  1993       Impact factor: 2.073

2.  Fine needle aspiration (FNA) cytology of the breast: the influence of unsatisfactory samples on patient management.

Authors:  E J Lazda; G Kocjan; V R Sams; A C Wotherspoon; I Taylor
Journal:  Cytopathology       Date:  1996-08       Impact factor: 2.073

3.  A one year audit of fine needle aspiration cytology for the pre-operative diagnosis of breast disease.

Authors:  A Hitchcock; C M Hunt; A Locker; J Koslowski; S Strudwick; C W Elston; R W Blamey; I O Ellis
Journal:  Cytopathology       Date:  1991       Impact factor: 2.073

4.  Fine needle aspiration cytology in lieu of open biopsy in management of primary breast cancer.

Authors:  H J Wanebo; P S Feldman; M C Wilhelm; J L Covell; R L Binns
Journal:  Ann Surg       Date:  1984-05       Impact factor: 12.969

5.  Audit of diagnostic accuracy of FNA cytology specimens taken by the histopathologist in a symptomatic breast clinic.

Authors:  L A Brown; S B Coghill; S A Powis
Journal:  Cytopathology       Date:  1991       Impact factor: 2.073

6.  Analysis of the causes of false negative cytology reports on breast cancer fine needle aspirates.

Authors:  M P Cariaggi; P Bulgaresi; M Confortini; L Bonardi; C Maddau; N Matucci; S Ciatto
Journal:  Cytopathology       Date:  1995-06       Impact factor: 2.073

  6 in total
  1 in total

1.  Clinical audit of repeat fine needle aspiration in a general cytopathology service.

Authors:  Rachna Goyal; Pankaj Kumar Garg; Arati Bhatia; Vinod Kumar Arora; Navjeevan Singh
Journal:  J Cytol       Date:  2014-01       Impact factor: 1.000

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.