Literature DB >> 9184457

Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.

V S Lee1, S E Solomonidis, W D Spence.   

Abstract

A system for measuring the stump-socket interface pressure was designed and built using a strain gauged type load cell. The system was utilized to study the pressure distribution in the quadrilateral and ischial containment type sockets. Two volunteer trans-femoral amputees fitted with both types of socket participated in the experiments. Pressures were measured while the subjects were standing and during walking. The maximum pressure recorded for standing was 34 kPa and for walking 95 kPa. Comparison made between the two sockets indicated that higher pressures were recorded at the proximal brim of the quadrilateral socket whereas the ischial containment socket produces a more evenly distributed pressure profile. The pressure distribution on the medial and lateral walls of both types of socket were similar but in the anterior and posterior walls, significant differences were noted. The results obtained from this study were compared with those found in published literature and the biomechanics of the two types of socket is discussed.

Mesh:

Year:  1997        PMID: 9184457     DOI: 10.1243/0954411971534287

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  8 in total

1.  Use of diaphragm transducers in the measurement of pressures on soft materials.

Authors:  J H Jhoun; D S Childress
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

2.  Ultrasound image matching using genetic algorithms.

Authors:  T S Douglas; S E Solomonidis; W A Sandham; W D Spence
Journal:  Med Biol Eng Comput       Date:  2002-03       Impact factor: 2.602

3.  Nature's answer to breaching the skin barrier: an innovative development for amputees.

Authors:  C J Pendegrass; A E Goodship; J S Price; G W Blunn
Journal:  J Anat       Date:  2006-07       Impact factor: 2.610

4.  Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study.

Authors:  Amr M El-Sayed; Nur Azah Hamzaid; Kenneth Y S Tan; Noor Azuan Abu Osman
Journal:  ScientificWorldJournal       Date:  2015-04-05

5.  Piezoelectric bimorphs' characteristics as in-socket sensors for transfemoral amputees.

Authors:  Amr M El-Sayed; Nur Azah Hamzaid; Noor Azuan Abu Osman
Journal:  Sensors (Basel)       Date:  2014-12-10       Impact factor: 3.576

Review 6.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

7.  Development of Prototype Low-Cost QTSS™ Wearable Flexible More Enviro-Friendly Pressure, Shear, and Friction Sensors for Dynamic Prosthetic Fit Monitoring.

Authors:  Valter Dejke; Mattias P Eng; Klas Brinkfeldt; Josephine Charnley; David Lussey; Chris Lussey
Journal:  Sensors (Basel)       Date:  2021-05-28       Impact factor: 3.576

8.  Determining the porous structure for optimal soft-tissue ingrowth: An in vivo histological study.

Authors:  Mukai Chimutengwende-Gordon; Robert Dowling; Catherine Pendegrass; Gordon Blunn
Journal:  PLoS One       Date:  2018-10-29       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.