Effect of leak location on measured respirator fit.

C D Crutchfield1, D L Park.   

Abstract

A significant difference in leak detection as a function of leak location was observed during a study assessing how well current models of quantitative fit-test systems detect leakage. Known sources of leakage (matched hypodermic needles) were introduced at three fixed locations into factory-probed half-mask and full-face respirators mounted on a headform-breathing machine system. The leak locations were the bridge of the nose, the cheek, and the chin. Baseline leakage into each respirator was determined by conducting a fit-test with all fixed leak sources capped. Fit tests were repeated with each individual source uncapped. Study objectives included determining (1) how well each system measured the leakage, and (2) whether leak location had any effect on leak measurement. An ambient aerosol fit-test system (Portacount Plus) and a controlled negative pressure (CNP) fit-test system (FitTester 3000) were used. The ambient aerosol system detected an overall average of 37.2% of the known leakage, with a coefficient of variation of 44.7%. An analysis of variance showed significant differences in aerosol system measurements of leakage as a function of leak location and mask type (p < 0.001). A different pattern of aerosol leak detection as a function of leak location was observed between half-mask and full-face respirators, which appears to be related to differences in in-mask airflow dynamics. The CNP system detected an overall average of 97.9% of the known leakage through the same hypodermic needles, with a coefficient of variation of 4.3%. CNP system results were not affected by leak location (p > 0.43) or mask type (p > 0.32).

Mesh:

Substances:

Year:  1997        PMID: 9183835     DOI: 10.1080/15428119791012649

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  2 in total

1.  Evaluation of full-facepiece respirator fit on fire fighters in the municipality of Jeddah, Saudi Arabia.

Authors:  Mansour A Balkhyour
Journal:  Int J Environ Res Public Health       Date:  2013-01-14       Impact factor: 3.390

2.  Experimental Measurement of the Size of Gaps Required to Compromise Fit of an N95 Respirator.

Authors:  Eugenia O'Kelly; Anmol Arora; Sophia Pirog; James Ward; P John Clarkson
Journal:  Disaster Med Public Health Prep       Date:  2022-01-21       Impact factor: 1.385

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.