Literature DB >> 9180087

Catheter-based radiotherapy to inhibit restenosis after coronary stenting.

P S Teirstein1, V Massullo, S Jani, J J Popma, G S Mintz, R J Russo, R A Schatz, E M Guarneri, S Steuterman, N B Morris, M B Leon, P Tripuraneni.   

Abstract

BACKGROUND: In animal models of coronary restenosis, intracoronary radiotherapy has been shown to reduce the intimal hyperplasia that is a part of restenosis. We studied the safety and efficacy of catheter-based intracoronary gamma radiation plus stenting to reduce coronary restenosis in patients with previous restenosis.
METHODS: Patients with restenosis underwent coronary stenting, as required, and balloon dilation and were then randomly assigned to receive catheter-based irradiation with iridium-192 or placebo. Clinical follow-up was performed, with quantitative coronary angiographic and intravascular ultrasonographic measurements at six months.
RESULTS: Fifty-five patients were enrolled; 26 were assigned to the iridium-192 group and 29 to the placebo group. Angiographic studies were performed in 53 patients (96 percent) at a mean (+/-SD) of 6.7+/-2.2 months. The mean minimal luminal diameter at follow-up was larger in the iridium-192 group than in the placebo group (2.43+/-0.78 mm vs. 1.85+/-0.89 mm, P=0.02). Late luminal loss was significantly lower in the iridium-192 group than in the placebo group (0.38+/-1.06 mm vs. 1.03+/-0.97 mm, P=0.03). Angiographically identified restenosis (stenosis of 50 percent or more of the luminal diameter at follow-up) occurred in 17 percent of the patients in the iridium-192 group, as compared with 54 percent of those in the placebo group (P= 0.01). There were no apparent complications of the treatment.
CONCLUSIONS: In this preliminary, short-term study of patients with previous coronary restenosis, coronary stenting followed by catheter-based intracoronary radiotherapy substantially reduced the rate of subsequent restenosis.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9180087     DOI: 10.1056/NEJM199706123362402

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  65 in total

Review 1.  Early and late effects of radiation treatment for prevention of coronary restenosis: a critical appraisal.

Authors:  O F Bertrand; S Lehnert; R Mongrain; M G Bourassa
Journal:  Heart       Date:  1999-12       Impact factor: 5.994

2.  Intravascular radiotherapy: restenosis and more?

Authors:  P Wexberg; M Gottsauner-Wolf
Journal:  Heart       Date:  2000-05       Impact factor: 5.994

Review 3.  Revascularization strategies in patients with diabetes: evolving concepts.

Authors:  J J Brennan; H S Cabin
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

Review 4.  Fortnightly review: Intracoronary stents.

Authors:  M M Gandhi; K D Dawkins
Journal:  BMJ       Date:  1999-03-06

5.  Monte Carlo dose simulation for intracoronary radiation therapy with a rhenium 188 solution-filled balloon with contrast medium.

Authors:  Eun-Hee Kim; Dae Hyuk Moon; Seung-Jun Oh; Chang-Woon Choi; Sang-Moo Lim; Myeong-Ki Hong; Seong-Wook Park
Journal:  J Nucl Cardiol       Date:  2002 May-Jun       Impact factor: 5.952

6.  Effective management of stable angina.

Authors:  M Petticrew; M Sculpher; J Kelland; R Elliott; D Holdright; M Buxton
Journal:  Qual Health Care       Date:  1998-06

7.  Drug eluting coronary stents.

Authors:  N P Jenkins; B D Prendergast; M Thomas
Journal:  BMJ       Date:  2002-12-07

Review 8.  New approaches to preventing restenosis.

Authors:  Balram Bhargava; Ganesan Karthikeyan; Alexandre S Abizaid; Roxana Mehran
Journal:  BMJ       Date:  2003-08-02

Review 9.  Indications for percutaneous and surgical revascularisation: how far does the evidence base guide us?

Authors:  P M Schofield
Journal:  Heart       Date:  2003-05       Impact factor: 5.994

10.  Intracoronary brachytherapy for in-stent restenosis: will it remain a viable therapy?

Authors:  Seong-Wook Park; Myeong-Ki Hong; Seung Jun Oh; Dae Hyuk Moon
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-06-16       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.