Literature DB >> 9178514

A cell-based immunobiosensor with engineered molecular recognition--Part I: Design feasibility.

V B Pizziconi1, D L Page.   

Abstract

A novel bioelectronic sensor is described in which living immune cells are transformed into unique biotransducer couples by engineering their molecular recognition for preselected antigens of clinical interest. This 'hybrid' biosensor, constructed with mast cells interfaced to a microfabricated thermoelectric device with the use of biomolecular linkages, is capable of detecting antigens in real time by transducing minute heat changes arising from antigen-induced mast cell activation processes. The thermoelectric approach was selected based upon preliminary bioenergetic calculations which indicated that metabolic changes arising from mast cell antigen recognition result in a significant increase in exothermic heat relative to basal metabolic conditions. Experimental studies confirmed that mast cell activation and degranulation can be discriminated theramally from basal metabolic activity. Results obtained from microcalorimetry experiments using cultured mast cells (MC/9) mucosal-like mast cell line), and harvested mast cells (rat peritoneal mast cells) indicated that detectable increases in heat output (-3 +/- 0.5 pW/cell, mean peak output) immediately followed cell activation. The construction of a miniature hybrid immunobiosensor device was made possible by bioelectronic coupling achieved with the use of cellular adhesive proteins that immobilized non-adherent (MC/9) cells as well as adherent (RBL-2H3 rat basophilic leukemia) cells to the thermopile. Results from preliminary tests conducted on a hybrid biosensor prototype validated the design feasibility of a miniature, living cell immunodiagnostic biosensor. Such cell-based hybrid biosensor approaches may greatly extend the capability for selective, rapid, on-site, antigen detection for a wide range of clinically relevant antigens and offer new approaches to in vitro diagnostics.

Entities:  

Mesh:

Year:  1997        PMID: 9178514     DOI: 10.1016/s0956-5663(96)00068-1

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Development of a frozen cell array as a high-throughput approach for cell-based analysis.

Authors:  Jean Philippe Stephan; Silvia Schanz; Anne Wong; Peter Schow; Wai Lee T Wong
Journal:  Am J Pathol       Date:  2002-09       Impact factor: 4.307

Review 2.  What heat is telling us about microbial conversions in nature and technology: from chip- to megacalorimetry.

Authors:  Thomas Maskow; Richard Kemp; Friederike Buchholz; Torsten Schubert; Baerbel Kiesel; Hauke Harms
Journal:  Microb Biotechnol       Date:  2009-06-01       Impact factor: 5.813

3.  Carbon nanotube electric immunoassay for the detection of swine influenza virus H1N1.

Authors:  Dongjin Lee; Yogesh Chander; Sagar M Goyal; Tianhong Cui
Journal:  Biosens Bioelectron       Date:  2011-01-28       Impact factor: 10.618

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.