Literature DB >> 9172122

Retained surgical needle in the perineum. Report of a case with a novel method of search and rescue.

S J Kleinpeter1, R C Kline, M A Finan.   

Abstract

BACKGROUND: Retrieval of a broken or lost surgical needle can be a difficult task, often requiring extensive surgical exploration. CASE: A surgical needle was retained in the perineum. Needle-hookwire placement with biplane fluoroscopy allowed the precise localization and marking of the foreign body; surgical removal without extensive exploration was therefore possible.
CONCLUSION: The use of needle-hookwire localization with biplane fluoroscopy should be considered for retrieval of foreign bodies in the perineum.

Mesh:

Year:  1997        PMID: 9172122

Source DB:  PubMed          Journal:  J Reprod Med        ISSN: 0024-7758            Impact factor:   0.142


  2 in total

1.  Retained surgical items and minimally invasive surgery.

Authors:  Verna C Gibbs
Journal:  World J Surg       Date:  2011-07       Impact factor: 3.352

2.  Surgical Retrieval of an Impaled Tapestry Needle from the True Pelvic Cavity of a Child-An Unusual Case Report.

Authors:  Nirmal Raj Gopinathan; Rakesh John; Himanshu Kanwat; Pebam Sudesh
Journal:  J Orthop Case Rep       Date:  2017 Sep-Oct
  2 in total