Literature DB >> 9170038

Signal-to-noise analysis of cerebral blood volume maps from dynamic NMR imaging studies.

J L Boxerman1, B R Rosen, R M Weisskoff.   

Abstract

The use of cerebral blood volume (CBV) maps generated from dynamic MRI studies tracking the bolus passage of paramagnetic contrast agents strongly depends on the signal-to-noise ratio (SNR) of the maps. The authors present a semianalytic model for the noise in CBV maps and introduce analytic and Monte Carlo techniques for determining the effect of experimental parameters and processing strategies upon CBV-SNR. CBV-SNR increases as more points are used to estimate the baseline signal level. For typical injections, maps made with 10 baseline points have 34% more noise than those made with 50 baseline points. For a given peak percentage signal drop, an optimum TE can be chosen that, in general, is less than the baseline T2. However, because CBV-SNR is relatively insensitive to TE around this optimum value, choosing TE approximately equal to T2 does not sacrifice much SNR for typical doses of contrast agent. The TR that maximizes spin-echo CBV-SNR satisfies TR/T1 approximately equal to 1.26, whereas as short a TR as possible should be used to maximize gradient-echo CBV-SNR. In general, CBV-SNR is maximized for a given dose of contrast agent by selecting as short an input bolus duration as possible. For image SNR exceeding 20-30, the gamma-fitting procedure adds little extra noise compared with simple numeric integration. However, for noisier input images, can be the case for high resolution echo-planar images, the covarying parameters of the gamma-variate fit broaden the distribution of the CBV estimate and thereby decrease CBV-SNR. The authors compared the analytic noise predicted by their model with that of actual patient data and found that the analytic model accounts for roughly 70% of the measured variability of CBV within white matter regions of interest.

Entities:  

Mesh:

Year:  1997        PMID: 9170038     DOI: 10.1002/jmri.1880070313

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  22 in total

Review 1.  Perfusion-weighted magnetic resonance imaging of the brain: techniques and application in children.

Authors:  Thierry A G M Huisman; A Gregory Sorensen
Journal:  Eur Radiol       Date:  2003-06-25       Impact factor: 5.315

Review 2.  Physiologic MRI for assessment of response to therapy and prognosis in glioblastoma.

Authors:  Mark S Shiroishi; Jerrold L Boxerman; Whitney B Pope
Journal:  Neuro Oncol       Date:  2015-09-12       Impact factor: 12.300

3.  Acute dural venous sinus thrombosis without brain parenchymal abnormality: assessment with cerebral blood volume using dynamic susceptibility contrast magnetic resonance imaging.

Authors:  Kyo Noguchi; Hideo Hamada; Michiya Kubo; Masashi Shimizu; Hikaru Seto
Journal:  Radiat Med       Date:  2006-11-24

4.  ASFNR recommendations for clinical performance of MR dynamic susceptibility contrast perfusion imaging of the brain.

Authors:  K Welker; J Boxerman; A Kalnin; T Kaufmann; M Shiroishi; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2015-04-23       Impact factor: 3.825

5.  Comparison of dynamic susceptibility-weighted contrast-enhanced MR methods: recommendations for measuring relative cerebral blood volume in brain tumors.

Authors:  Eric S Paulson; Kathleen M Schmainda
Journal:  Radiology       Date:  2008-09-09       Impact factor: 11.105

Review 6.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

7.  Simultaneous perfusion and permeability measurements using combined spin- and gradient-echo MRI.

Authors:  Heiko Schmiedeskamp; Jalal B Andre; Matus Straka; Thomas Christen; Seema Nagpal; Lawrence Recht; Reena P Thomas; Greg Zaharchuk; Roland Bammer
Journal:  J Cereb Blood Flow Metab       Date:  2013-03-06       Impact factor: 6.200

8.  Abnormalities in the recirculation phase of contrast agent bolus passage in cerebral gliomas: comparison with relative blood volume and tumor grade.

Authors:  Alan Jackson; Andrea Kassner; Deborah Annesley-Williams; Helen Reid; Xiau-Ping Zhu; Kah-Loh Li
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

9.  Slice-accelerated gradient-echo echo planar imaging dynamic susceptibility contrast-enhanced MRI with blipped CAIPI: effect of increasing temporal resolution.

Authors:  Tomohiro Takamura; Masaaki Hori; Koji Kamagata; Kanako K Kumamaru; Ryusuke Irie; Akifumi Hagiwara; Nozomi Hamasaki; Shigeki Aoki
Journal:  Jpn J Radiol       Date:  2017-10-31       Impact factor: 2.374

10.  Contrast agent dose effects in cerebral dynamic susceptibility contrast magnetic resonance perfusion imaging.

Authors:  Jeffry R Alger; Timothy J Schaewe; Tom C Lai; Andrew J Frew; Paul M Vespa; Maria Etchepare; David S Liebeskind; Jeffrey L Saver; S Chelsea Kidwell
Journal:  J Magn Reson Imaging       Date:  2009-01       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.