Literature DB >> 9169571

Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study.

J C Wong1, C Studholme, D J Hawkes, M N Maisey.   

Abstract

In routine clinical work, registration accuracy is assessed by visual inspection. However, the accuracy of visual assessment of registration has not been evaluated. This study establishes the limits of visual detection of misregistration in a registered brain fluorine-18 fluorodeoxyglucose positron emission tomography to magnetic resonance image volume. The "best" registered image volume was obtained by automatic registration using mutual information optimization. Translational movements by 1 mm, 2 mm, 3 mm and 4 mm, and rotational movements by 1 degrees , 2 degrees , 3 degrees and 4 degrees in the positive and negative directions in the x- (lateral), y- (anterior-posterior) and z- (axial) axes were introduced to this standard. These 48 images plus six "best" registered images were presented in random sequence to five observers for visual categorization of registration accuracy. No observer detected a definite misregistration in the "best" registered image. Evaluation for inter-observer variation using observer pairings showed a high percentage of agreement in assigned categories for both translational and rotational misregistrations. Assessment of the limits of detection of misregistration showed that a 2-mm translational misregistration was detectable by all observers in the x- and y-axes and 3-mm translational misregistration in the z-axis. With rotational misregistrations, rotation around the z-axis was detectable by all at 2 degrees rotation whereas rotation around the y-axis was detected at 3-4 degrees . Rotation around the x-axis was not symmetric with a positive rotation being identified at 2 degrees whereas negative rotation was detected by all only at 4 degrees. Therefore, visual analysis appears to be a sensitive and practical means to assess image misregistration accuracy. The awareness of the limits of visual detection of misregistration will lead to increase care when evaluating registration quality in both research and clinical settings.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9169571     DOI: 10.1007/BF00841402

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  6 in total

1.  Synergistic imaging.

Authors:  M N Maisey; D J Hawkes; A M Lukawieck-Vydelingum
Journal:  Eur J Nucl Med       Date:  1992

2.  Automated three-dimensional registration of magnetic resonance and positron emission tomography brain images by multiresolution optimization of voxel similarity measures.

Authors:  C Studholme; D L Hill; D J Hawkes
Journal:  Med Phys       Date:  1997-01       Impact factor: 4.071

Review 3.  Correlative image registration.

Authors:  D A Weber; M Ivanovic
Journal:  Semin Nucl Med       Date:  1994-10       Impact factor: 4.446

4.  Accuracy of registration of PET, SPECT and MR images of a brain phantom.

Authors:  T G Turkington; R J Jaszczak; C A Pelizzari; C C Harris; J R MacFall; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

5.  Adjustable computerized stereotaxic brain atlas for transmission and emission tomography.

Authors:  C Bohm; T Greitz; D Kingsley; B M Berggren; L Olsson
Journal:  AJNR Am J Neuroradiol       Date:  1983 May-Jun       Impact factor: 3.825

6.  Head fixation device for reproducible position alignment in transmission CT and positron emission tomography.

Authors:  M Bergström; J Boëthius; L Eriksson; T Greitz; T Ribbe; L Widén
Journal:  J Comput Assist Tomogr       Date:  1981-02       Impact factor: 1.826

  6 in total
  5 in total

1.  A hybrid strategy to integrate surface-based and mutual-information-based methods for co-registering brain SPECT and MR images.

Authors:  Yuan-Lin Liao; Yung-Nien Sun; Wan-Yuo Guo; Yuan-Hwa Chou; Jen-Chuen Hsieh; Yu-Te Wu
Journal:  Med Biol Eng Comput       Date:  2010-12-30       Impact factor: 2.602

2.  Validation of ictal single photon emission computed tomography with depth encephalography and epilepsy surgery.

Authors:  Vijay M Thadani; Alan Siegel; Petra Lewis; Adrian M Siegel; Barbara C Jobst; Karen L Gilbert; Terrance M Darcey; David W Roberts; Peter D Williamson
Journal:  Neurosurg Rev       Date:  2003-07-04       Impact factor: 3.042

3.  Registration of in vivo prostate MRI and pseudo-whole mount histology using Local Affine Transformations guided by Internal Structures (LATIS).

Authors:  Chaitanya Kalavagunta; Xiangmin Zhou; Stephen C Schmechel; Gregory J Metzger
Journal:  J Magn Reson Imaging       Date:  2014-04-04       Impact factor: 4.813

4.  Acceptance test of a commercially available software for automatic image registration of computed tomography (CT), magnetic resonance imaging (MRI) and 99mTc-methoxyisobutylisonitrile (MIBI) single-photon emission computed tomography (SPECT) brain images.

Authors:  Gianfranco Loi; Marco Dominietto; Irene Manfredda; Eleonora Mones; Alessandro Carriero; Eugenio Inglese; Marco Krengli; Marco Brambilla
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

5.  Importance of Veins for Neurosurgery as Landmarks Against Brain Shifting Phenomenon: An Anatomical and 3D-MPRAGE MR Reconstruction of Superficial Cortical Veins.

Authors:  Santino Ottavio Tomasi; Giuseppe Emmanuele Umana; Gianluca Scalia; Roberto Luis Rubio-Rodriguez; Pier Francesco Cappai; Crescenzo Capone; Giuseppe Raudino; Bipin Chaurasia; Maurizio Salvati; Nicolas Jorden; Peter A Winkler
Journal:  Front Neuroanat       Date:  2020-12-15       Impact factor: 3.856

  5 in total