Literature DB >> 9166230

Potential of electrospray mass spectrometry for quantifying glycohemoglobin.

N B Roberts1, B N Green, M Morris.   

Abstract

An electrospray ionization-mass spectrometric procedure has been developed for determining glycohemoglobin. Whole-blood samples from 78 diabetic and 50 nondiabetic subjects (glycation range 3-15%, as determined by electrospray mass spectrometry) were diluted 500-fold in an acidic denaturing solvent and introduced directly into a mass spectrometer. The resulting mass spectra were then processed to estimate the percentage of glycohemoglobin present in the sample. Total analysis time, including plotting the spectra and computing the percentage of glycation, was approximately 3 min. The imprecision (CV) of the method was < 5.1% for inter- and intrabatch analyses for total glycohemoglobin in the range 3.6-14%. Comparison of the mass spectrometric results with those from established affinity chromatographic procedures showed good overall agreement. The relative glycation of the alpha- and beta-chains was determined directly and was shown to be constant (0.64:1) over the glycation range measured. Only single glucose attachment to both the alpha- and beta-chains was observed.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9166230

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  9 in total

Review 1.  Glycated haemoglobin in the year 2000.

Authors:  E S Kilpatrick
Journal:  J Clin Pathol       Date:  2000-05       Impact factor: 3.411

2.  Electrospray ionisation mass spectrometry: principles and clinical applications.

Authors:  C S Ho; C W K Lam; M H M Chan; R C K Cheung; L K Law; L C W Lit; K F Ng; M W M Suen; H L Tai
Journal:  Clin Biochem Rev       Date:  2003

3.  Covalent modifications of hemoglobin by nitrite anion: formation kinetics and properties of nitrihemoglobin.

Authors:  Mai Otsuka; Sarah A Marks; Daniel E Winnica; Andrew A Amoscato; Linda L Pearce; Jim Peterson
Journal:  Chem Res Toxicol       Date:  2010-10-20       Impact factor: 3.739

4.  Hot electron capture dissociation distinguishes leucine from isoleucine in a novel hemoglobin variant, Hb Askew, beta54(D5)Val-->Ile.

Authors:  Jonathan P Williams; Andrew J Creese; David R Roper; Brian N Green; Helen J Cooper
Journal:  J Am Soc Mass Spectrom       Date:  2009-05-18       Impact factor: 3.109

5.  Multivariate analysis of matrix-assisted laser desorption/ionization mass spectrometric data related to glycoxidation products of human globins in nephropathic patients.

Authors:  Annunziata Lapolla; Eugenio Ragazzi; Barbara Andretta; Domenico Fedele; Michela Tubaro; Roberta Seraglia; Laura Molin; Pietro Traldi
Journal:  J Am Soc Mass Spectrom       Date:  2007-02-22       Impact factor: 3.109

6.  Higher degree of glycation of hemoglobin S compared to hemoglobin A measured by mass spectrometry: Potential impact on HbA1c testing.

Authors:  Kuanysh Kabytaev; Shawn Connolly; Curt L Rohlfing; David B Sacks; Alexander V Stoyanov; Randie R Little
Journal:  Clin Chim Acta       Date:  2016-04-22       Impact factor: 3.786

7.  Glycoproteomic analysis of human lung adenocarcinomas using glycoarrays and tandem mass spectrometry: differential expression and glycosylation patterns of vimentin and fetuin A isoforms.

Authors:  Jung-Hyun Rho; Michael H A Roehrl; Julia Y Wang
Journal:  Protein J       Date:  2009-05       Impact factor: 2.371

Review 8.  Maillard Proteomics: Opening New Pages.

Authors:  Alena Soboleva; Rico Schmidt; Maria Vikhnina; Tatiana Grishina; Andrej Frolov
Journal:  Int J Mol Sci       Date:  2017-12-12       Impact factor: 5.923

9.  Quantitative analysis of a novel antimicrobial peptide in rat plasma by ultra performance liquid chromatography-tandem mass spectrometry.

Authors:  Ruo-Wen Zhang; Wen-Tao Liu; Lu-Lu Geng; Xiao-Hui Chen; Kai-Shun Bi
Journal:  J Pharm Anal       Date:  2011-07-26
  9 in total